background image

 

7

 

WARNING 

 

At 60

°

C (140

°

F) hot water can produce third 

degree burns in 6 seconds; at 54

°

C (130

°

F) in 30 

seconds. Maximum thermostat setting is 41

°

(106

°

F). 

 
 

2.4.1) Precautions 

against 

freeze-ups 

 
To avoid damage to the swimming pool heater, pump, filter, piping and 
other accessories, make sure that the circulating pump is "ON" and that 
there is adequate circulation of water through all these components to 
prevent freeze-up when the outside temperature is below 0°C (32°F). If 
the swimming pool heater is to be turned off at temperatures below the 
freezing point, the water piping at the inlet and outlet of the swimming 
pool heater must be disconnected. Also, it must be drained by opening 
the drain valve at the bottom as well as the air vent, to allow the 
introduction of air into the primary circuit of your pool heater. Then, the 
feed water line must be bled by removing the 1/2’’ NPT plug (I) located 
at the bottom of the T fitting located after the water feeder and regulator 
device. 
 
 

2.5) 

SHUT DOWN AT THE END OF THE 
SWIMMING SEASON 

 
 

2.5.1) Outside 

installation 

 
1.  Make sure that the HMP-03 ON-OFF switch (D) and the 

circulating pump switch are OFF; 

2. 

Make sure that power supply switch is OFF; 

3. 

Disconnect the water inlet and outlet of the HMP-03 swimming 
pool heater; 

4. 

Open the drain valve (O) located on the bottom of the HMP-03 
unit and drain it completely; 

5. 

Removed the ½’’ plug (I) from the T fitting located on the right end 
side of the water feeder & regulator device (J); 

6. 

Leave the drain valve open during all shut down periods. 

 
 

2.5.2) Inside 

installation 

 

3. 

For inside installations protected from freezing, we suggest you 
follow the same procedure than article 2.5.1 at the exception that 
you can leave it full of water for the winter shutdown period. This 
apply only for an installation protect against cool temperature. 

 
 

2.5.3) Prolonged 

non-use 

or 

winterization 

of the oil burner 

 
When the oil burner will not be used for an extended period of time OR 
the appliance is not used altogether, follow this procedure: 
 
1) 

Close the valve located at the bottom of the oil tank that feeds the 
burner; 

2) 

Raise the thermostat to call for heat and cause the oil burner to 
start; 

3) 

Let the burner fire until there is no longer a flame and combustion 
is cut by the safety (usually 30 to45 seconds after the flame 
extinguishes) 

4) 

Depress the red Re-start Button; the burner should start. If there is 
still a flame, repeat the procedure until there is no more flame. 

5)  When you have assured yourself that steps 3) and 4) are 

completed, shut-off the electrical power to the unit. 

2.6) 

START-UP AT THE BEGINNING OF THE 
SWIMMING SEASON 

 
Have the chimney and the connecting pipes swept (INSIDE 
INSTALLATION ONLY). 
Have all heating surfaces cleaned if deemed necessary after a visual 
check. To clean the tubes of the heat exchanger, remove the smoke 
box and the flue baffles. 
 
 

CAUTION 

The HMP-03 being equipped with a sound trap, 
make sure not to damage the acoustical material 
when cleaning the boiler. The use of a flexible 
cleaning brush is strongly recommended. 

 
 
1. 

To clean the combustion chamber removes the burner; 

2. 

Replace the oil filter and nozzle; 

3.  Have the burner electrodes cleaned along with the burner 

retention head; 

4. 

Close the drain valve (O), install the ½’’ plug (I) to the T fitting and 
install the inlet and outlet water pipes as showed in figure 3; 

5. 

Make sure that oil valve is open; 

6. 

The power supply interrupter should be "ON"; 

7.  Start the filter pump and wait until the air is completely bled 

through the HMP-03 unit; 

8. 

Select the "ON" position on the HMP-03 switch located on the 
front panel; 

9. 

Refer to section 2.2 for the burner start up. 

 
 

2.6.1)  Regular maintenance during 

the heating season 

 
 

2.6.2) Nozzle 

 
3. 

A dirty or clogged nozzle can prevent ignition or cause odors 
and smoke. It must be replaced. 

 
 

2.6.3) Fuel 

tank 

 
Regularly check the level tank. Should it run dry, the lines will have to 
be bled before restarting the burner. 
 
 

2.7) PRECAUTIONS 

 
Never use your swimming pool heater as an incinerator. Never pile or 
store paper or garbage near it. 
 
 
 

Содержание ICP HMP-03

Страница 1: ...Rev E Save these instructions for future reference Caution Do not tamper with the unit or its controls Call a qualified service technician Model HMP 03 D N S 0 5 2 6 R é v A Manufactured by UTC Canada Corporation ICP Division 3400 Industrial Boulevard Sherbrooke Quebec J1L 1V8 ...

Страница 2: ...is extra power comes from the uniquely designed heat exchanger coupled with a high efficiency oil burner The pool water will rapidly reach its desired temperature under any climatic conditions The HMP 03 need not be in operation if the pool is not used We suggest that the heater be used based on need only in order to avoid unnecessary expenses To fully enjoy the power of your appliance use it only...

Страница 3: ...utdoor Diffuser Kit The HMP 03 swimming pool heater must be installed with the Outdoor Diffuser Kit model GDK manufactured by ICP Canada according to the following instructions also see Figure 2 p 10 1 Remove the top flue pipe cover part F and the top casing panel part G 2 Insert the 6 inch diameter exhaust pipe in the smoke box collar align the pre drilled holes of the exhaust pipe with the flue ...

Страница 4: ... for voiding the warranty 1 7 2 Outdoor diffuser kit model GDK With the outdoor diffuser kit no draft regulator is needed and the maximum over fire draft should be 0 045 W C after 5 minutes of operation 1 8 BURNER INFORMATION The oil burner of the swimming pool heater is factory installed and wired The nozzle is also installed but the technician must do the final air adjustment The burner is facto...

Страница 5: ...ter is not clogged check the vacuum reading and make sure it is less than 6 in hg for a one pipe system and 12 in hg for a two pipes system 4 Check the electrical supply circuits breakers 5 Check the burner electrode adjustments refer to the burner instruction manual 6 Check if the pool thermostat is calling for heat 7 Check if the low water cut off green light is on 8 Check for air in the oil pum...

Страница 6: ...d for an extended period of time OR the appliance is not used altogether follow this procedure 1 Close the valve located at the bottom of the oil tank that feeds the burner 2 Raise the thermostat to call for heat and cause the oil burner to start 3 Let the burner fire until there is no longer a flame and combustion is cut by the safety usually 30 to45 seconds after the flame extinguishes 4 Depress...

Страница 7: ...ater level Q Observation door F Red light low water level R Pool heater water outlet G Low water cut off S Operation and Hi limit control HI 180 160 o F LOW 170 150 o F H Pool thermostat sensor location T Pool heater water inlet I 1 2 NPT drain plug U Safety valve at the back of the appliance J Feed water regulator and check valve device V Expansion tank K Outlet water temperature sensor location ...

Страница 8: ...e telephone Day Night Dealer name and address START UP TEST RESULTS Nozzle Pressure lb psi Burner adjustments Primary air Fine air Draw Assembly CO2 Smoke scale Bacharach Gross stack temperature 0 F Ambient temperature 0 F Chimney draft W C Overfire draft W C Test performed by ...

Страница 9: ...FIGURE 2 GDK 24 Installation 10 DNS 0524 Rev A ...

Страница 10: ...FIGURE 3 Typical Piping Arrangement 11 DNS 0525 Rev A ...

Страница 11: ...12 FIGURE 4 Wiring Diagram DNS 0518 Rev B ...

Страница 12: ...7 Right side panel B02135 01 28A Top front panel ass y HMP 03 D only B02148 01 ITEM DESCRIPTION NUMBER 28B Top front panel ass y HMP 03 T only B02148 02 29 Front door ass y B02151 30 Water leak pan B02117 31 Front underneath covert B02116 32 Observation door ass y B01842 33 AFG V1 burner ass y B01532 01 34 Hex nut 3 8 16NC zinc F07F011 35 Oil inlet tube B01467 36 Gasket fixed flange N04Z026 37 Dra...