P/N 1062800 • REV B • ISS 01JUL11
VR1910VR1910-R3VR1910WDMVR1910WDM-R3VR1920VR1920-R3VR1930WDMVR1930WDM-R3
IFS Fiber Module Installation & Operation Instructions
VT1910VT1910-R3VT1910WDMVT1910WDM-R3VT1920VT1920-R3VT1930WDMVT1930WDM-R3
Страница 1: ...S 01JUL11 VR1910 VR1910 R3 VR1910WDM VR1910WDM R3 VR1920 VR1920 R3 VR1930WDM VR1930WDM R3 IFS Fiber Module Installation Operation Instructions VT1910 VT1910 R3 VT1910WDM VT1910WDM R3 VT1920 VT1920 R3 VT1930WDM VT1930WDM R3 ...
Страница 2: ... WIRE RS485 DATA ON 1 ON ON 2 Data Input Data Input Output Data Input Output Data Input 6 5 4 3 2 1 Data Output Data Output Data Input NOT USED ON 1 OFF ON 2 NOTE Switch 3 ON will pass data OFF will pass Tamper Switch status and data from VR to VT but not from VT to VR FUNCTIONALITY OF TAMPER SWITCH The tamper switch terminals on the VR will open upon one of the following conditions loss of carrie...
Страница 3: ...Video monitor Duplex multimode fiber optic cable Switch 1 NOTE Switch 3 ON will pass data OFF will pass Tamper Switch status and data from VR to VT but not from VT to VR RS232 RS422 RS485 2 wire RS485 4 wire Switch 2 OFF OFF OFF OFF ON OFF ON ON TAMPER SWITCH 1 2 SW 2 1 232 OFF OFF 422 OFF OFF 2W 485 ON OFF 4W 485 ON ON 1 2 SW 2 1 3 3 232 OFF OFF 422 OFF OFF 2W 485 ON OFF 4W 485 ON ON OFF TAMPER S...
Страница 4: ...es A B VR1900 B A Carrier Detect Power LED illuminates 1 2 1 2 3 1 2 RS232 ON RS422 1 2 1 2 RS485 2 WIRE 1 2 RS485 4 WIRE 1 2 NOT USED NOTE WITHOUT PROPER FIBER CONNECTION LED s DO NOT INDICATE CORRECT OPERATIONAL STATUS OF THE UNIT ...
Страница 5: ...s reasonable efforts the parties will negotiate an equitable adjustment in price d The preceding paragraph sets forth the exclusive remedies for claims based on defect in or failure of products or services whether the claim is in contract indemnity warranty tort including Seller s negligence strict liability or otherwise and however instituted Upon the expiration of the warranty period all such li...
Страница 6: ...blication library To access the library go to our website at the following location http www interlogix com transmission1 Sales and support contact information North America Toll free 855 286 8889 in the US including Alaska and Hawaii Puerto Rico Canada Outside the toll free area 503 885 5700 E mail techsupport interlogix com Europe Select Contact Us at www utcfssecurityproducts eu Australia secur...
Страница 7: ...and remove securement screws for printed circuit board 4 If there are multiple boards to the assembly continue removing securement screws until none are left 5 Lift off printed circuit board 6 Disassembly of box version of product is complete For rack version 1 Locate and remove securement screws for printed circuit board Usually but not limited to at least 4 screws 2 If there are multiple boards ...
Страница 8: ...erference in which case the user may be required to take adequate measures Canada This Class A digital apparatus complies with Canadian ICES 003 Cet appareil numérique de la classe A est conforme à la norme NMB 003 du Canada European Union directives 2004 108 EC EMC directive Hereby UTC Fire Security declares that this device is in compliance with the essential requirements and other relevant prov...