background image

 

 

Regulatory information 

Manufacturer 

PLACED ON THE MARKET BY: 
UTC Fire & Security Americas Corporation, Inc. 
3211 Progress Drive, Lincolnton, NC, 28092, USA
AUTHORIZED EU REPRESENTATIVE: 
UTC Fire & Security B.V. 
Kelvinstraat 7, 6003 DH Weert, Netherlands 

Product warnings 
and disclaimers 

THESE PRODUCTS ARE INTENDED FOR SALE 
TO AND INSTALLATION BY QUALIFIED 
PROFESSIONALS. UTC FIRE & SECURITY 
CANNOT PROVIDE ANY ASSURANCE THAT 
ANY PERSON OR ENTITY BUYING ITS 
PRODUCTS, INCLUDING ANY “AUTHORIZED 
DEALER” OR “AUTHORIZED RESELLER”, IS 
PROPERLY TRAINED OR EXPERIENCED TO 
CORRECTLY INSTALL FIRE AND SECURITY 
RELATED PRODUCTS. 
For more information on warranty disclaimers and 
product safety information, please check 

https://firesecurityproducts.com/policy/product-
warning/

 or scan the QR code. 

Certification 

 

European Union 
directives 

UTC Fire & Security hereby declares that this 
device is in compliance with the applicable 
requirements and provisions of the Directive 
2014/30/EU and/or 2014/35/EU. For more 
information see www.utcfireandsecurity.com or 
www.interlogix.com. 

 

2012/19/EU (WEEE directive): Products marked 
with this symbol cannot be disposed of as 
unsorted municipal waste in the European Union. 
For proper recycling, return this product to your 
local supplier upon the purchase of equivalent 
new equipment, or dispose of it at designated 
collection points. For more information see: 
www.recyclethis.info. 

Содержание interlogix ShatterPro 3

Страница 1: ...base to prevent tampering Hand clap test In addition to a test mode you can test the detector by clapping your hands Optional tamper switch Sends a signal to the control panel when the cover is removed from the base You will need the following tools and parts to install the detector ShatterPro 3 detector including cover screw Screws and wall anchors Flat blade screwdriver Phillips screwdriver UTC ...

Страница 2: ... test it before permanently mounting the detector To install the detector do the following 1 Run the security system wiring to the detector location 2 Remove the front cover of the detector as follows Round housing Press the release tab on the lip of the base twist the cover counter clockwise and lift the cover off Figure 4 below Figure 4 Round housing parts Microphone LED Release tab Rectangle ho...

Страница 3: ...are unsure about the glass type 2 To put the detector in test mode hold the tester so that the speaker is within 1 in 25 mm of the detector microphone Figure 8 below and activate the tester When the detector is in test mode the LED on the detector lights steady for 4 seconds and then flashes for 60 seconds The relay opens for 4 seconds then returns to standby Time resets after each valid test Figu...

Страница 4: ... to keep it free of dust and dirt Always test the detector after cleaning it Specifications Input voltage 9 5 to 16 VDC Current Typical Maximum 15 mA 25 mA Electrical configuration Form A Form C Relay rating 16 V 50 mA max Tamper switch rating 12 V 50 mA max Detection range 3 to 25 ft 0 9 to 7 6 m x 360 Alarm response 4 seconds Minimum glass size 12 x 24 in 30 5 x 61 cm Recommended glass thickness...

Страница 5: ...D PRODUCTS For more information on warranty disclaimers and product safety information please check https firesecurityproducts com policy product warning or scan the QR code Certification European Union directives UTC Fire Security hereby declares that this device is in compliance with the applicable requirements and provisions of the Directive 2014 30 EU and or 2014 35 EU For more information see...

Отзывы: