background image

 

NX-4V2 LED Keypad User Manual 

Step 2 Enter your 4 or 6 digit user code to arm the system. 

•  The armed and exit lights will illuminate. 
•  You  may now leave the building. 

Arming your system in the “STAY mode” 

STAY  is used when  the  user is inside the premise and wants  protection  around 
the  perimeter. Listed below  are the  steps to arm in the  STAY  Mode: 

Step 1 Close all protected doors and windows. 

•  Ready light must be on or flashing when  all protected zones and sensors are 

secure.  Note:  If  any  zones  are bypassed, a sensor in that  zone  can  be 
violated  without  affecting  the 

ready light. 

•  The security  system will not arm if the 

ready light 

is not on  or flashing. 

•  If the 

power  light 

is off,  you  have  no AC power. Restore  power if possible. If 

not,  contact  your  installing  company  for service. 

Step 2 Enter your 4 or 6 digit user code.  

•  If the “Auto Bypass” is enabled, all interior zones will be bypassed if you  do 

not leave through  a designated entry/exit  door. If “Auto Bypass” is enabled, 
omit step 3. 

•  When “Auto Instant”  is enabled, if you do not leave through  a designated 

entry/exit  door the  instant  light  will  illuminate  indicating that  the  entry/exit 
doors no longer have an entry  delay. If  an “Auto Instant”  is enabled, omit step 
4. 

Step 3 

• Press the [STAY] key. 

•  The 

bypass light 

will  illuminate  indicating that  all interior  zones  are bypassed. 

(All  interior devices will bypass  automatically,  giving the  user freedom  of 
movement  within  the interior  area.) 

•  For each interior zone bypassed, the corresponding 

zone light 

will  also 

illuminate.  If  any  zone(s)  have  been bypassed previously  by the  user,  the 
light(s)  corresponding  to the  bypassed zone(s)  will illuminate,  alerting  the  user 
that  a zone(s)  may  be unprotected  and can  be faulted  without  an alarm. 

•  The 

stay light 

will also illuminate.  Note: normally,  all entry/exit  doors will  be 

delayed. 

Step 4 

• To change entry/exit to “Instant”, press the [STAY] key again. 

•  The 

instant light 

will  illuminate  indicating that  the  entry/exit  doors have  no 

delay. 

•  To change entry/exit  to “Delayed”,  press the [

STAY

]  key again. 

Содержание Interlogix NX-4V2

Страница 1: ...NX 4V2 LED Keypad User Manual P N I NX4V2 OM REV C NOV12 ...

Страница 2: ...echnologies Corporation All rights reserved Trademarks and patents Other trade names used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products Contact information www utcfireandsecurity com or www interlogix com Customer support www interlogix com customer support ...

Страница 3: ...e 6 Arming your system in the STAY mode 7 Using the Quick Arm optional 8 Changing modes while system armed 8 Disarming the system 8 CANCEL ABORT feature optional 8 Bypassing zones 9 Group bypass 9 Unbypassing 9 Turning the door chime ON and OFF 9 Adding and changing user codes 10 Assigning user code authority levels 11 Other keypad functions 11 Service menu 14 Emergency evacuation plans 16 System ...

Страница 4: ...ii NX 4V2 LED Keypad User Manual ...

Страница 5: ...FUNCTIONS Abort Delay σ Cancel Alarm Group Bypass σ Auto Bypass σ Chime Quick Arm σ Auto Instant Communicator Test Re Exit Battery Test Forced Arming σ Siren Test σ These features should not be enabled on UL listed systems ENTRY EXIT DELAY TIMES Exit Delay Time __________ Secondary Exit Delay Time ________ Entry Delay Time _________ Secondary Entry Delay Time _______ ZONE DESCRIPTIONS 01 _________...

Страница 6: ...and sounds mean will help you to easily operate your system READ THE ENTIRE MANUAL AND IF POSSIBLE PRACTICE ON THE KEYPAD CONTROL WHILE YOUR PROFESSIONAL INSTALLER IS ON SITE KEEP IN MIND THE LEVEL OF SECURITY YOU WILL OBTAIN WITH THIS SYSTEM RELATES SPECIFICALLY WITH TWO MAJOR FACTORS 1 The quantity quality and placement of security devices attached to this system 2 The knowledge you have of the ...

Страница 7: ...ain the A C Transformer after testing PLEASE READ THE FOLLOWING INFORMATION AND INSTRUCTIONS CAREFULLYBEFORE OPERATING YOUR SECURITYCONTROL SYSTEM IF YOU DO NOT UNDERSTAND ANYPORTION OF THIS MANUAL OR IF YOU HAVE ANY QUESTIONS ABOUT YOUR SYSTEM CONTACT THE INSTALLING COMPANY ...

Страница 8: ...on that allows the system to be turned on ARMED with one or more zones open A system that is ready to be force armed will flash the ready icon Note Those zones that are not ready will not create an alarm Function Code A Function Code is either a four 4 or six 6 digit code that has been programmed by the installer to operate a device Group Bypass An option that allows the user to bypass multiple zo...

Страница 9: ...A steady fire light means a fire zone has been faulted A rapidly flashing fire light means that a fire zone is in a trouble condition Power Light The power light is on if the primary power is on The power light will flash if the system has a low battery condition Ready Light The ready light is on when the system is ready to arm and flashes if ready to force arm The ready light is off when the syst...

Страница 10: ...d a local audible alarm when pressed for two seconds If your system is connected to a monitoring center an emergency report could be transmitted to that center Note Some Panic Hold Up alarms are programmed to be silent at the protected site while reporting an alarm to the monitoring center Check with your installing company to determine how your security system will respond to the Panic Hold Up ac...

Страница 11: ...hrough a designated entry exit door If Auto Bypass is enabled omit step 3 When Auto Instant is enabled if you do not leave through a designated entry exit door the instant light will illuminate indicating that the entry exit doors no longer have an entry delay If an Auto Instant is enabled omit step 4 Step 3 Press the STAY key The bypass light will illuminate indicating that all interior zones are...

Страница 12: ... to be off at this time if you plan on re entering the building otherwise you can create an alarm You may re initiate an exit entry delay by pressing the STAY key again The instant light will go out Disarming the system When you enter the protected area through one of the designated Entry Exit doors the keypad control will sound a solid tone for the duration of the entry delay time or until you en...

Страница 13: ...s the BYPASS key again or press the key to exit the Bypass Mode The bypass light will stop flashing upon exiting the Bypass Mode Group bypass By pressing the BYPASS key followed by the 0 0 key then the BYPASS key again all zones that are designated as group bypass zones will be bypassed Press the BYPASS key again to exit group bypassing Unbypassing To manually unbypass zones perform the bypassing ...

Страница 14: ...r r r r r for a 4 digit code or r r r r r r for a 6 digit code 6 The ready light will flash indicating you are back at Step 4 above If the code is rejected the sounder will beep 3 times NOTE To delete a user code enter for a 4 digit code or for a 6 digit code 7 The ready light will flash indicating you are back at Step 4 above If the code is rejected the sounder will beep 3 times 8 If another user...

Страница 15: ...the authority level by pressing the number for that authority level see Table 3 below Table 3 Authority levels Ligh t Authority level if light 8 is off 1 Reserved Note Do not change if on 2 Arm Only 3 Arm Only After Close Window 4 Master Arm Disarm can program other codes 5 Arm Disarm 6 Bypass Zones 7 Open Close Reporting 8 If this light is on the code is programmed as a function code Do not chang...

Страница 16: ... the siren Walk test If enabled it will permit a temporary walk through test where all zones become silent and do not report alarms to the central station 1 Press Chime user code During this test the chime light will flash on the LED keypad 2 Each time a zone is faulted the zone light on the LED keypad will illuminate and the chime will sound The number of the faulted zone s will be displayed on t...

Страница 17: ...e Must always be two 2 digits Example The 5 th would be entered as 0 5 6 Enter the last two digits of the Year Code Example For 2007 enter 0 7 Setting the system 1 Press 9 7 2 Enter the Master Code 3 Enter the hour code which must be two 2 digits Note The clock is a 24 hour clock Refer Table 4 below 4 Enter the minutes code which must be two 2 digits Example 7 minutes after would be entered 0 7 Ta...

Страница 18: ...nges and a low battery is detected Pulses when the armed status changes and a Tamper condition is detected Beeps to indicate Telephone Line Cut if selected Pulses when one or more of the following conditions are detected Zone or Box Tamper Low Battery AC Power Fail or Expander trouble Beeps 3 times every minute indicating a low battery or missing transmitter is detected if wireless device is in sy...

Страница 19: ...UPERVISION Press the 4 key and the zone light s will illuminate showing which zone s has loss of supervision This only applies to wireless zones Press key to return to the 1 of 8 service lights 5 ZONE TROUBLE Press the 5 key and the zone light s will illuminate showing which zone s has a trouble condition Press the key to return to the 1 of 8 service lights 6 TELEPHONE FAULT Press the 6 key The zo...

Страница 20: ...ice escape procedures In a home sleep with bedroom door closed this will increase your escape time If you suspect fire test the door for heat If you think it is safe brace your shoulder against the door and open it cautiously Be ready to slam the door if smoke or heat rush in Practice escaping to the outdoors and meeting in an assigned spot Call the Fire Department from a neighbor s phone Note Aft...

Страница 21: ...NX 4V2 LED Keypad User Manual 17 System notes ...

Отзывы: