64x64 Router
3-9
Operation
Operation
Fan Service
Alarm indicators on the individual boards or front of the unit indicate fan problems. Individual
fans can be removed and carefully disconnected using the small screws and mating connec-
tors. Make sure the key is aligned properly when reconnecting.
FIGURE 3-5.
Fan device location
Rear Panel Overview
MX Bus (control bus)
All routing switcher chassis in the system must be interconnected with the MX Bus cable, with
the two free ends terminated. In the case of a stand-alone system, both connectors must be
terminated.
Monitor Matrix BNC
This allows the user to switch up an additional output that can look at the output of any other
output modules present in the system. Monitor Matrix is only functional on the primary cross-
point. Monitor Matrix data rate is limited to 360Mb per second.
Sync BNCs
Two additional midplane BNC connectors are used for loop through for the AES reference
signal -- in the case of an audio router, and NTSC (or PAL) blackburst in a video router.