Wednesday, May 16, 2007
Page 2
Green = Power
okay
Green = U-Net port active
Green = U-Net hub receiving
data from SC-4/400
8) U-Net
Terminators are
supplied. USI
Part # 65324-04
The U-Net control bus supports a maximum of 255 control panels. The
use of a U-Net hub does not increase the total number of panels
supported, it only increases the potential length of the U-Net CAT-5 cable.
Connect to U-Net port on
the SC-4 or SC-400 frame
using standard CAT-5
cable. Maximum length
from SC-4/400 frame to this
connection 1000'.
Redundant power
supply connectors.
Each port may have up to 32 control panels
and a maximum of 1000' of CAT-5 cable. All
ports must be terminated either on the U-Net
hub or the control panel.
SC Control System
U-Net
Hub
Router
Control
Panel
Router
Control
Panel
Router
Control
Panel
Cat-5
Cable
U-Net
Terminator
Port 1
Po
rt 0
Po
rt
5
Port 2
Port 6
U-Net Terminator
Por
t 3
Po
rt 4
Router
Control
Panel
Port 8 Port 7
U-Net
Terminator
USI Part #80263-2