USSC Logwood 1261 Скачать руководство пользователя страница 5

WRONG

RIGHT

5

Operation of the Heater

1.

2.

3.

4.

5.
6.
7.
8.

FIG. 6

FIG. 5

ELBOW

COLLAR

THIMBLE

PIPE  REDUCER

FLOOR PROTECTOR

FLOOR PROTECTOR

3 FT. MIN.

2 FT. MIN

10 FT.

CHIMNEY CAP MANDATORY

11 FT. MINIMUM

FIG. 7

WRONG

FLUE CONNECTION-NON-COMBUSTIBLE WALL

PIPE

NONCOMBUSTIBLE WALL

PIPE

BAROMETRIC
DRAFT REGULATOR

BAROMETRIC
DRAFT REGULATOR

PIPE

NONCOMBUSTIBLE
CONSTRUCTION IN
ACCORDANCE WITH
NFPA 211

BE SURE TO PUT A LAYER OF SAND OR FIREBRICK
APPROXIMATELY 1 1/2" THICK IN THE BOTTOM OF THE
STOVE BEFORE STARTING FIRE.
Burn wood or wood products only. The wood should be air dried
for at least six months prior to use for maximum efficiency.
After the fire has been started and is burning satisfactorily,
adjust the rate of burning by opening or closing the draft
damper wheel on the feed door.
Never build extremely large fires in this type of heater as
damage to the heater or smoking may result.
Provide air into the room for combustion.
Do Not touch the heater after firing until it has cooled.
Do Not use a grate or elevate fire, build fire directly on hearth.
The fuel feed door must remain closed during operation.

Crimped end of the pipe must be installed toward the heater.
The pipe should slide into the flue collar. The pipe should be
firmly attached to the flue collar with 3 screws and sealed with
furnace cement.
Slope any horizontal pipe upward toward the chimney at least
1/4 " inch for each foot of horizontal run.
You must have at least 18" inches clearance between any
horizontal piping and the ceiling. (Fig. 2)
The pipe cannot extend into the chimney flue.(Fig. 7)
Seal each connector pipe joint with furnace cement. Also seal
the pipe at the chimney.
Use 3 sheet metal screws at each joint to make the piping rigid.
It is recommended that no more than two (2) 90 degree bends
be used in the stove pipe installation as more than two (2) may
decrease the amount of draw and possibly cause smoke
spillage.

1.

2.

3.

4.
5.

6.
7.

Chimney Connection

MASONRY CHIMNEY
The masonry chimney must comply with UL codes.  Before using
an existing masonry chimney, clean the chimney and inspect the
flue liner to be sure it is safe to use. Make repairs before attaching
the heater. See Page 3, Item 5.  Look at Fig. 5. The connector pipe
and fittings you will need to connect directly to a masonry chimney
are shown.  If the connector pipe must go through a combustible wall
before entering the masonry chimney, consult a qualified mason or
chimney dealer. The installation must conform to local fire codes,
and NFPA 211.  Do not connect this heater into the same chimney
flue as the fireplace or flue from another heater.  The chimney used
for a heater must not be used to ventilate the cellar or basement. If
there is a cleanout opening at the base of the chimney, close it
tightly.

UL/ULC LISTED CHIMNEY
Carefully follow chimney manufacturer's instructions. Use only
listed type HT per UL 103, 6-in diameter black or blued chimney
connector, minimum 24 gauge steel. If your chimney starts at the
ceiling (Fig. 6), you will need enough 6" pipe to reach the ceiling.
The top of the chimney must be at least 3 feet above the roof and
be at least 2 feet higher than any point of the roof within 10 feet. (Fig
6)

RULES FOR CONNECTOR PIPE INSTALLATION

NOTE:  The chimney connector shall not pass through an
attic, roof space, floor, ceiling, or similar concealed space.
Where passage through a wall or partition of combustible
construction is desired, the installation must conform with
NFPA 211.

Содержание Logwood 1261

Страница 1: ...TAIN EFFICIENT DEPENDABLE SERVICE FROM THE HEATER AND ENABLE YOU TO ORDER REPAIR PARTS CORRECTLY KEEP IN A SAFE PLACE FOR FUTURE REFERENCE UNITED STATES STOVE COMPANY 227 Industrial Park Road P O Box 151 South Pittsburg TN 37380 423 837 2100 COMPANY U NITED STATES STOV E C S S U Owner Owner Owner Owner Owners Manual s Manual s Manual s Manual s Manual Logwood 1261 85029E EPA EXEMPT PER METHOD 28A ...

Страница 2: ...tric Drill Bit 1 8 Dia For Sheet Metal Screws Adjustable Wrench Screw Driver Blade Type Gloves Safety Glasses MATERIALS 6 Elbow Collar and Thimble As Required 24 gauge min 1 2 Sheet Metal Screws No 10A x 1 2 6 Diameter 24 gauge black or blued steel Underwriters Laboratories UL Listed Residential Type HT 2100 F Chimney or use a Masonry Chimney in good repair Floor Protector Material R value 2 0 Siz...

Страница 3: ...w anyone to use this heater who is unfamiliar with the correct opera tion of the heater 1 2 3 4 5 6 7 8 9 10 11 12 13 14 For further information on using your heater safely obtain a copy of the National Fire Pro tection Association NFPA publication Using Coal and Wood Stoves Safely NFPA No HS 10 1978 The address of the NFPA is Batterymarch Park MA 02269 Disposal of Ashes Place ashes in a metal con...

Страница 4: ...ace the stove in your selected location Install stove pipe elbows and thimble as necessary utilizing either a recently cleaned and inspected masonry chimney properly lined or a UL Listed chimney Insure that the damper provided is installed in the flue collar Again check the following illustrations and be sure you have the clearances shown from the heater and the connector pipe to combustible surfa...

Страница 5: ... seal the pipe at the chimney Use 3 sheet metal screws at each joint to make the piping rigid It is recommended that no more than two 2 90 degree bends be used in the stove pipe installation as more than two 2 may decrease the amount of draw and possibly cause smoke spillage 1 2 3 4 5 6 7 Chimney Connection MASONRY CHIMNEY The masonry chimney must comply with UL codes Before using an existing maso...

Страница 6: ... be connected to a masonry chimney by passing through a combustible wall NFPA Standard 211 allows the following wall pass through systems MASONRY CHIMNEY CONSTRUCTED TO NFPA 211 AIRTIGHT CLEANOUT DOOR FLOOR PROTECTOR COMBUSTIBLE WALL TO HEATER CHIMNEY CONNECTOR CEILING SEE PARTS A B C D AND E OF THIS FIGURE FOR OPTIONS CHIMNEY FLUE FIGURE 8 CONNECTION OF CHIMNEY CONNECTOR TO A MASONRY CHIMNEY THRO...

Страница 7: ... tor by means of sheet steel support plates on both ends of the chimney section The opening in the combustible wall shall be covered and the chimney section supported on both sides with sheet steel supports which are at least 24 gauge 0 024 in thickness The sheet steel supports shall be securely fastened to wall surfaces on all sides and shall be sized to fit and hold the chimney section Fasteners...

Страница 8: ...INIMUM FACTORY BUILT CHIMNEY LENGTH SHEET STEEL SUPPORTS CHIMNEY SECTION CHIMNEY CONNECTOR AIR SPACE 2 IN TWO VENTILATED AIR CHANNELS EACH 1 INCH CONSTRUCTED OF SHEET STEEL PART C FIGURE 8 PART D FIGURE 8 MASONRY CHIMNEY CONSTRUCTED TO NFPA 211 SHEET STEEL SUPPORTS 24 GAUGE MIN THICKNESS CHIMNEY CONNECTOR TO HEATER MINIMUM CHIMNEY CLEARANCES FROM MASONRY TO SHEET STEEL SUPPORTS AND COMBUSTIBLES 2 ...

Страница 9: ...rgequantity of coarse salt baking soda or cool ashes on top of the fire in the firebox CAUTION A chimney fire may cause ignition of wall studs or rafters which you thought were a safe distance from the chimney If you have a chimney fire have your chimney inspected by a qualified person before using again Service Hints Do not expect a heater to draw It is the chimney that creates the draft Smoke sp...

Страница 10: ...0304 40305 40306 40307 40308 40332 D6 83427 89971 89972 89973 89974 89975 89589 85029 DESCRIPTION REAR LEG FRONT LEG MAIN BOTTOM MAIN SIDE MAIN BACK HEARTH PLATE SLIDING DRAFT PLATE DOOR FRAME DOOR MAIN TOP PIVOTING TOP LID LID SUPPORT LID LIFTER FLUE COLLAR SOLID FLUE DAMPER DOOR PINS HANDLE LATCH NUTS HANDLE EXTENSION HANDLE BRACKET PARTS BAG OWNERS MANUAL QNTY 2 2 1 2 1 1 1 1 1 1 1 2 1 1 1 1 2 ...

Страница 11: ...NOTES 11 ...

Страница 12: ...EN WRITING ALWAYS GIVE THE FULL MODEL NUMBER WHICH IS ON THE NAMEPLATE ATTACHED TO THE BACK OF THE HEATER WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION AS SHOWN IN THIS LIST 1 The PART NUMBER 2 The PART DESCRIPTION 3 The MODEL NUMBER 1261 4 The SERIAL NUMBER UNITED STATES STOVE COMPANY 227 Industrial Park Road P O Box 151 South Pittsburg TN 37380 423 837 2100 www USSTOVE com ...

Отзывы: