USSC Fuego B2045L Скачать руководство пользователя страница 26

26

26

26

26

26

NOTES

NOTES

NOTES

NOTES

NOTES

Содержание Fuego B2045L

Страница 1: ... ou cannot reac ou cannot reac ou cannot reac ou cannot reach y h y h y h y h your gas supplier our gas supplier our gas supplier our gas supplier our gas supplier call call call call call the fire department the fire department the fire department the fire department the fire department Installation and service must be performed by a Installation and service must be performed by a Installation an...

Страница 2: ... is imperative that control compartments burners and circulating air passageways of the appliance be kept clean IMPORTANT SAFETY INFORMATION 3 4 PRODUCT FEATURES 4 SPECIFICATIONS 5 CONTENTS 5 ITEMS REQUIRED FOR INSTALLATION 6 INSTALLATION 7 MANTEL CLEARANCES 8 GAS CONNECTION 9 10 GAS PRESSURE CHECK 10 FLAME APPEARANCE 11 LOG ASSEMBLY 11 OPERATING INSTRUCTIONS 12 14 CLEANING SERVICING 14 15 FLAME A...

Страница 3: ...NOXIDEPOISONING Earlysignsofcarbonmonoxidepoisoningaresimilartothefluwith headaches dizziness and or nausea If you have these signs obtain fresh air immediately Have the heater serviced as it may not be operating properly The installation must conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 The B2045N B2045L vent free gas heater system cannot b...

Страница 4: ...pingsystemduring any pressure testing of that system at test pressures in excess of 1 2 psig 3 5 kPa Theappliancemustbeisolatedfromthegassupplypipingsystembyclosingitsequipmentshutoffvalveduring any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa Do not use this room heater if any part has been under water Immediately call a qualified servi...

Страница 5: ...ROM LOOSE FIBERS LOGS LOGS TO PREVENT SKIN IRRITATION FROM LOOSE FIBERS LOGS LOGS TO PREVENT SKIN IRRITATION FROM LOOSE FIBERS LOGS LOGS TO PREVENT SKIN IRRITATION FROM LOOSE FIBERS LOGS LOGS TO PREVENT SKIN IRRITATION FROM LOOSE FIBERS LOGS ARE FRAGILE HANDLE WITH CARE ARE FRAGILE HANDLE WITH CARE ARE FRAGILE HANDLE WITH CARE ARE FRAGILE HANDLE WITH CARE ARE FRAGILE HANDLE WITH CARE Carefully ins...

Страница 6: ...ng which complies with local codes Sediment trap Pipe sealant approved for use with Pipe wrench propane LPG resistant to sulfur compounds CODES CODES CODES CODES CODES Adheretoalllocalcodesorintheirabsence thelatesteditionofTHENATIONALFUELGASCODEANSIZ223 1 or NFPA54 which can be obtained from American National Standards Institute Inc American National Standards Institute Inc American National Stan...

Страница 7: ...uction uction uction pr pr pr pr pro o o o ovide vide vide vide vide adequate combustion and ventilation air by one of the methods described in the adequate combustion and ventilation air by one of the methods described in the adequate combustion and ventilation air by one of the methods described in the adequate combustion and ventilation air by one of the methods described in the adequate combus...

Страница 8: ...mum clearances between mantel shelf and the top of the heater If your installation does not meet the below minimum clearances you must Raise the mantel to an acceptable height OR Remove the mantel ALL MINIMUM DISTANCES ARE IN INCHES TOP OF HEATER DISTANCE TO UNDERSIDE OF MANTEL UNDERSIDE OF MANTEL SHELF MANTEL SHELF BACK WALL FLOOR MINIMUM CLEARANCE TO BACK WALL ...

Страница 9: ...ter to allow full gas when permitted by local codes Only use pipe of 1 2 or greater diameter to allow full gas when permitted by local codes Only use pipe of 1 2 or greater diameter to allow full gas when permitted by local codes Only use pipe of 1 2 or greater diameter to allow full gas volume to heater Excessive pressure loss will occur if the pipe is too small volume to heater Excessive pressur...

Страница 10: ...e heater for leaks using soap and water solution after completing connection DO NOT USE AN OPEN FLAME The heater regulator controls the burner pressure which should be checked at the pressure test point located on the front of the main control and is accessible through the front of the heater see FIGURE 6 The pressure should be checked with the heater burning and the control set to high HI The pre...

Страница 11: ...NING LOG POSITIONING LOG POSITIONING LOG POSITIONING Do not handle these logs with your bare hands Always wear gloves to prevent skin irritation from ceramic fibers After handling logs wash your hands gently with soap and water to remove any traces of fibers PROPER INSTALLATION SEQUENCE PROPER INSTALLATION SEQUENCE PROPER INSTALLATION SEQUENCE PROPER INSTALLATION SEQUENCE PROPER INSTALLATION SEQUE...

Страница 12: ...cally lights the pilot If Piezo fails thenlightthepilotusingmatches Refertomatchlightinginstructions page14 Whenlightingthepilot follow theseinstructionsexactly BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS WHAT TO DO IF YOU SMELL GAS WHAT TO DO IF YOU SMEL...

Страница 13: ...n valve knob clockwise to ON 10 Wait about one minute then turn burner switch D to ON It will take a few minutes for the thermopile located on top of the pilot to heat up NOTE If unit is equipped with remote on off wall switch switch must be in on position for burner to light 11 Adjust flame height with the high low knob C 12 Turn on all electrical power to the appliance 13 Close access door NOTE ...

Страница 14: ...e pilot flame should always be present when the heaterisinoperationandshouldjusttouchthetopofthe thermocouple tip FIGURE 9 Ifthepilotflamedoesnottouchthethermocouple then the main burner is unlikely to function reliably FIG URE 10 WARNING WARNING WARNING WARNING WARNING Turn off heater and allow to cool before cleaning Turn off heater and allow to cool before cleaning Turn off heater and allow to ...

Страница 15: ...ning Inspection Annual Cleaning Inspection Annual Cleaning Inspection Annual Cleaning Inspection Inspect and clean burner air intake holes Inspect and clean all burner ports Inspect ODS pilot for operation and accumulation of lint at air intake holes Verify flame pattern and log placement for proper operation Verify smooth and responsive ignition of main burner and rear burner In normal operation ...

Страница 16: ... HEATER ASSEMBLY REPLACEMENT PARTS HEATER ASSEMBLY REPLACEMENT PARTS HEATER ASSEMBLY REPLACEMENT PARTS HEATER ASSEMBLY REPLACEMENT PARTS HEATER ASSEMBLY REPLACEMENT PARTS 17 16 15 14 13 12 11 8 9 10 7 6 5 3 2 1 4 18 ...

Страница 17: ...VER FRAME 1 9 89917 EXTRUDED LOUVER SHORT 4 10 89916 EXTRUDED LOUVER LONG 2 11 24772B FIREBOX WRAPPER 1 12 24892 HEAT SHIELD 2 13 69295B FRONT WELDMENT 1 14 69236B WINDOW FRAME ASSEMBLY 1 15 83323 8 32 x 3 8 MACHINE SCREW 1 16 24457B CONTROL DOOR 1 17 89899 BRASS KNOB 1 N S 89824 MAGNETIC LATCH 1 N S 83343 10 x 1 2 HX HD SCREWS 86 18 24886B ROCKER SWITCH BRACKET 1 PARTS LIST FOR HEATER ASSEMBLY PA...

Страница 18: ...18 18 18 18 18 BURNER LOG ASSEMBLY BURNER LOG ASSEMBLY BURNER LOG ASSEMBLY BURNER LOG ASSEMBLY BURNER LOG ASSEMBLY 11 1 17 15 16 14 3 2 8 7 9 10 6 4 5 12 13 ...

Страница 19: ...T 2 3 81198 CONTROL VALVE NATURAL 1 81202 CONTROL VALVE LIQUID PROPANE 1 4 83464 10 32 x 3 8 PH HD MACHINE SCREW 4 5 89937 BURNER GAS LINE 31 ORIFICE NAT 1 89938 BURNER GAS LINE 49 ORIFICE L P 1 N S 83172 10A x 1 2 HX HD SCREW 2 to MOUNT PILOT 11 6 89921 O P AMERICA NAT PILOT 1 89922 O P AMERICA L P PILOT 1 7 89855 PILOT TUBE 11 1 8 89856 3 16 LOXIT FITTING 1 9 89841 3 16 COMPRESSION NUT 1 10 8984...

Страница 20: ...ong Ignitor electrode is broken Ignitor electrode not connected to ignitor cable Ignitor cable pinched or wet keep ignitor cable dry Broken ignitor cable Bad piezo ignitor Appliance burning vapors from paint hair spray glues etc Gas leak Not enough fresh air is available for ODS Pilot to operate Low line pressure ODS Pilot is partially clogged Gas leak Control valve defective Gas supply turned off...

Страница 21: ...lator Problem will stop after a few hours of operation Run the heater with the damper open if you have one or open a window for the first few hours Log heater is intended to be smokeless Turn OFF heater and callqualifiedserviceperson Turn control knob to LOW position and let warm up for a minute Operate burner until air is removed from line Have gas line checked by local gas company Clean burner o...

Страница 22: ...FOR THE B2045 THIS OPTIONAL F40 BLOWER KIT IS AVAILABLE WHERE YOU PURCHASED THIS HEATER OR YOU CAN ORDER DIRECT FROM THE FACTORY BY CONTACTING THE PARTS DEPARTMENT AT THE NUMBER AND ADDRESS ON THE BACK PAGE OF THIS MANUAL BACK VIEW OF 2045 MODEL RCK60 REMOTE CONTROL KIT REMOTE SKYTECH SKYTECH 1001 ON OFF INDICATOR R E M O T E NO OFF SKYTECH ...

Страница 23: ...Y WIRING DIAGRAM FOR GENERATOR ASSEMBLY WIRING DIAGRAM FOR GENERATOR ASSEMBLY 50 60 70 80 90 21 10 32 c 50 60 70 80 90 21 10 32 c MODEL WSK60 WALL SWITCH KIT OPTIONAL KITS FOR THE B2045 OPTIONAL KITS FOR THE B2045 OPTIONAL KITS FOR THE B2045 OPTIONAL KITS FOR THE B2045 OPTIONAL KITS FOR THE B2045 continued continued continued continued continued MODEL WTK60 WALL THERMOSTAT KIT ...

Страница 24: ...h to OFF STANDARD WIRING FROM FACTORY STANDARD WIRING FROM FACTORY STANDARD WIRING FROM FACTORY STANDARD WIRING FROM FACTORY STANDARD WIRING FROM FACTORY WIRING OF THE RCK60 REMOTE CONTROL KIT WIRING OF THE RCK60 REMOTE CONTROL KIT WIRING OF THE RCK60 REMOTE CONTROL KIT WIRING OF THE RCK60 REMOTE CONTROL KIT WIRING OF THE RCK60 REMOTE CONTROL KIT WIRING WITH THE WTK60 WALL THERMOSTAT KIT WIRING WI...

Страница 25: ...NTROL KIT THE RCK60 REMOTE CONTROL KIT THE RCK60 REMOTE CONTROL KIT Remember the Rocker Switch must be turned to OFF while using the Wall Switch PILOT O F F PILOT O N Sit E A TP TH TP TH ROCKER SWITCH CONTROL VALVE REMOTE CONTROL SENSOR PIGGYBACK DISCONNECT WALL SWITCH Note When combining these Optional kits you must remember that only one of them can be used at a time Example If you want to contr...

Страница 26: ...26 26 26 26 26 NOTES NOTES NOTES NOTES NOTES ...

Страница 27: ...OF OTHER WAR THIS WARRANTY IS EXPRESSLY IN LIEU OF OTHER WAR THIS WARRANTY IS EXPRESSLY IN LIEU OF OTHER WAR THIS WARRANTY IS EXPRESSLY IN LIEU OF OTHER WAR THIS WARRANTY IS EXPRESSLY IN LIEU OF OTHER WAR RANTIES EXPRESSORIMPLIED INCLUDINGTHEWARRANTY RANTIES EXPRESSORIMPLIED INCLUDINGTHEWARRANTY RANTIES EXPRESSORIMPLIED INCLUDINGTHEWARRANTY RANTIES EXPRESSORIMPLIED INCLUDINGTHEWARRANTY RANTIES EXP...

Страница 28: ...ING YOUR HEATER FILL IN THE SERIAL NUMBER IN THE SPACE PROVIDED ABOVE FOR YOUR RECORDS 1 The PART NUMBER PART NUMBER PART NUMBER PART NUMBER PART NUMBER 2 The PART DESCRIPTION PART DESCRIPTION PART DESCRIPTION PART DESCRIPTION PART DESCRIPTION 3 The MODEL NUMBER B2045N B2045L MODEL NUMBER B2045N B2045L MODEL NUMBER B2045N B2045L MODEL NUMBER B2045N B2045L MODEL NUMBER B2045N B2045L 4 The SERIAL NU...

Отзывы: