INSTALLATION

Please see all methods of Installation in
Appendix at the rear of this booklet.

                    Pipe to combustible:
                        Sides: 21"
                        Back: 18"
The installation must be made only on a
noncombustible floor.
     d) Install the smoke pipe connector to the
chimney with 26-gauge pipe and elbows (to be
purchased separately), maintaining the proper
clearances for the specific model.  Seal the smoke
pipe in the chimney with furnace cement. (The
chimney connector shall be securely supported,
and joints fastened with sheet metal screws or
rivets.)
     e) Install 8" diameter heat pipe to plenum of the
central hot air furnace.  Use 26-gauge pipe and
connectors (to be purchased separately).  (See
Fig. 15)  If central air conditioning is installed in the
plenum, install heat pipe above the air conditioning
unit.  Secure heat pipe connection with supports
and sheet metal screws.
     f) Connect electrical supply in the electrical
junction box that is mounted on the back of the
Furnace.  See Wiring Diagram (Fig. 11).  Remove
the cover from electrical junction box and connect
power supply wires to wires designated, using wire
nuts.  The power cord supplied may be used for
installation, if permitted by local codes and
regulations.  If the power cord supplied cannot be
used, the power supply wiring must be 90 degrees
centigrade in a metal cable and should be
completed by a qualified installer complying with
NFPA Standard No. 70 and local codes.
     g) Optional Plenum Fan Control Switch (Part
No. 11PCS) is available for installation on the
plenum of central hot air heating furnace.  The
purpose of this switch is to activate the circulating
fan of the central hot air heating furnace when the
temperature in the plenum exceeds 120 degrees
F.,  and  shut off the fan when the temperature in the
plenum is reduced to 100 degrees F.  This avoids
overheating the plenum.
   The electrical supply for operation of this fan
control switch is to be obtained from the same
electrical supply as the central hot air heating
system.  Follow the instructions of the wiring
diagram (Fig. 11).  Do not make connections across
Limit Control in the furnace.
       Make electrical wire connections in accordance
with NFPA Standard No. 70 and local codes in the
power supply junction box (See Fig. 13).  The wiring
to complete the connections should be 18 AWG
minimum copper and 90 degrees centigrade in a
cable.

          This is a furnace, not a free standing stove.
You must direct heated air from 8" outlets away from
the furnace, or it will not function properly.

1. This installation must be done by a qualified
heating equipment installer.
2.  The installation is to be done in compliance with
National Fire Protection Association installation
standards: No. 89M, 90B, 211, 70 (National       Elec-
trical Code) and Uniform Mechanical Code 913, 6-4,
in the states where applicable.  (Their code offers
connecting smoke pipe connectors into chimney
with other fuel burning appliances.)
3.  Rooms large in comparison with size of the
appliance:
     a) Wood or Coal Burning Furnace needs air for
combustion and circulation to house.
     b) Provision must be made to make up this air
and not starve gas or oil furnace of combustion air.
     c) Have "Authority Having Jurisdiction"         de-
termine that air is of adequate makeup.         (Refer-
ence N.F.P.A. Nos. 30&54, Code for        Installation
of Gas & Oil Equipment).
4.   Have "Authority Having Jurisdiction" is to inspect
all chimneys and installations for adequate venting
and for compliance with standard and local codes
and regulations regarding installation of wood  burn-
ing appliances.
5.   Installation for Supplemental Heat Application to
Existing Central System.  (See Fig. 2 for typical
installation.)
     a) Place Wood or Coal Burning Furnace so that
the chimney connector will be as short as practical
and avoiding unnecessary sharp turns in the smoke
pipe connector and the installation of devices that
would create excessive resistance to the flow of flue
gases.
     b) Locate the Wood or Coal Burning Furnace as
close as practical to the existing central hot air
heating system, maintaining clearances as stated
on the label on the fuel door.
    c) Clearance from combustible materials must
comply with those stated on the label on the fire
door:

Unit to combustible:

                       Front: 48"
                       Back: 30"
                       Sides: 12"
                       Plenum to Ceiling: 6"

Содержание Clayton 1537G

Страница 1: ...TALLATION MAY VOID YOUR WARRANTY DO NOT USE THIS FURNACE IN A MOBILE HOME OR TRAILER UNITED STATES STOVE COMPANY 227 Industrial Park Road P O Box 151 South Pittsburg TN 37380 423 837 2100 WARNOCKHERSEY R FOR PARALLEL INSTALLATION WITH EXISTING FORCED AIR GAS OR OIL FIRED FURNACE FOR INSTALLATION AS A CENTRAL FURNACE THE 1537G CLAYTON FURNACE HAS BEEN APPROVED FOR U S INSTALLATIONS ONLY 851340 5 98...

Страница 2: ...encil 6 Foot Folding Rule or Tape Tin Snips Drill Hand or Electric Drill Bit 1 8 Dia For Sheet Metal Screws Screw Driver Blade Type Gloves Sabre Saw 5 16 Nut Driver or 5 16 Socket w Ratchet MATERIAL 6 Pipe 6 Elbow Collar and Thimble as required 24 gauge min 1 2 Sheet Metal Screws 6 Inside diameter Listed Residential Type or Building Heating Appliance Chimney or existing masonry chimney Electrical ...

Страница 3: ...te with fuel loading or ash removal doors open DO NOT store fuels paints thinners flammable liquids or other highly volatile substances in the furnace room CAUTION HOT SURFACES Keep children away Do not touch during operation CAUTION INSPECT FLUE PIPES FLUE PIPE JOINTS AND FLUE PIPE SEALS REGULARLY TO ENSURE THAT SMOKE AND FLUE GASES ARE NOT DRAWN INTO AND CIRCULATED BY THE AIR CIRCULATION SYSTEM ...

Страница 4: ...rymarchPark Quincy MA02269 11 Keep the ashpit section free of excess ashes Do not allow ashes to stack higher than the sides of the ash pan 12 DISPOSAL OF ASHES Place ashes in a metal container with a tight fitting lid Keep the closed container on a noncombustible floor or on the ground well away from all combustible materials Keep the ashes in the closed container until all cinders have thoroughl...

Страница 5: ...operate in either parallel or series air flow arrangement with the central furnace or as a central fur nace CENTRAL FURNACE INSTALLATION As a central furnace the unit functions inde pendently of any other system The blower will come on when the plenum temperature reaches the setting on the blower control PARALLEL INSTALLATION U S ONLY See Optional Wiring Diagram Page 13 Fig 14 The design is such t...

Страница 6: ...6 32 1 8 1 3 4 9 33 7 8 49 1 8 24 1 16 40 11 16 Figure 1B 1400 1500 DIMENSIONS OF FURNACE FIGURE 1 1537G ...

Страница 7: ... pipe to sidewall 21 530mm Chimney connector pipe to backwall 18 460mm Hot air ducts to combustibles 6 150mm Refer to Fig 2 3 Place the furnace on a noncombus tible floor Check figures 2 and 3 Be sure you have the clearances shown from the furnace and the connector pipe to combustible surfaces If you have a solid brick or stone wall behind your furnace you can place the furnace as close as you wis...

Страница 8: ... as possible If the connector pipe must go through a combustible wall before entering the masonry chimney consult a qualified mason or chimney dealer The installation must conform to local fire codes and N F P A 211 DO NOT CONNECT THIS FURNACE TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE The chimney used for a furnace must not be used to ventilate the cellar or basement If there is a cleanout openi...

Страница 9: ...lude a section for a barometric draft regulator between the furnace and the chimney Fig 4 5 7 The barometric draft regulator must be installed in the same room same pressure zone as the furnace 8 Install the barometric draft regulator strictly in accordance with the instructions that are provided with the barometric draft regulator 9 A solid damper must be used in the chimney connecting pipes betw...

Страница 10: ...as in Figure 9 with screws and nuts provided Note Slotted holes are for adjustment of handle Adjust handle until some pressure is required to lock feed door during firing sequence Install Honeywell Fan Limit Control on rear of furnace cabinet as shown in Figure 10 Remove blower s from carton s Remove junction box cover Attach clip nuts as in Figure 10 Install blower s and gasket s with 1 4 20x3 4 ...

Страница 11: ... W 110 VAC 60 HZ GROUND G B W ELECTRICAL JUNCTION BOX M1 M2 M1 M2 BLOWER MOTOR BLOWER MOTOR WIRE NUT 7 PLACES IMPORTANT POWER SUPPLY WIRING MUST NOT BE LESS THAN 90 CENTIGRADE WIRE COLOR CODE G GREEN GROUND B BLACK POWER SUPPLY W WHITE POWER SUPPLY R1 WHITE FAN CONTROL R2 BLACK FAN CONTROL M1 BLACK BLOWER MOTOR M2 WHITE BLOWER MOTOR Fig 12 FIGURE 11 ...

Страница 12: ...e wiring diagram Fig 11 Do not make connections across Limit Control in the furnace Make electrical wire connections in accordance with NFPA Standard No 70 and local codes in the power supply junction box See Fig 13 The wiring to complete the connections should be 18 AWG minimum copper and 90 degrees centigrade in a cable This is a furnace not a free standing stove You must direct heated air from ...

Страница 13: ...to keep home at normal temperatures 3 Do not load fuel above bottom of feed door TO GAS OIL ELECTRIC TRANSFORMER AND COMBUSTION FAN OF SOLID FUEL UNIT H N POWER SUPPLY FURNACE BLOWER MOTOR FAN LIMIT COMBINATION CONTROL GAS OIL ELECTRIC POWER SUPPLY JUNCTION BOX JUMPER IN CAUTION DO NOT CONNECT PLENUM FAN CONTROL SWITCH ACROSS FURNACE LIMIT CONTROL Figure 13 6 MIN PLENUM ...

Страница 14: ...erature MEDIUM setting is normally satisfactory Set higher or lower for your comfort ADDING FUEL When starting a fire add small amounts of fuel instead of adding large quantities of fuel This will give more complete combustion and less build up of tars or soot in the chimney Set thermostat to HIGH before opening feed door Wood fire Add wood to a convenient level Coal Fire Never smother the fire wh...

Страница 15: ...ge 28 for list of trouble shooting tips 5 6 A draft reading of 05 to 06 w c is suggested for proper burning of this unit when using wood or bituminous coal as fuel When using anthracite coal this draft reading is a minimum reading CHIMNEY MAINTENANCE Creosote and Soot Formation and Need for Removal When wood is burned slowly it produces tar and other organic vapors which combine with expelled mois...

Страница 16: ...16 MODEL 1537G REPAIR PARTS ...

Страница 17: ...4757 FEED DOOR HANDLE ASSEMBLY 1 20 80145 LIMIT CONTROL 1 21 80231 JUNCTION BOX 1 22 89520 ROUND WOODEN HANDLE 1 23 23425 HANDLE BRACKET 2 24 68234 BLOWER THERMOSTAT BRACKET 1 25 22140 RELAY BOX BRACKET 1 26 23787 SMOKE DOOR CLIP 2 27 68733 THERMOSTAT PANEL ASSEMBLY INCLUDES A B C BELOW 27a 68732 COVER WELDMENT 1 27b 68722 THERMOSTAT PANEL 1 27c 86318 16GA WIRE LINK 543FT 28 24556 ASH DOOR HANDLE ...

Страница 18: ...L 11 RPT 90 ELBOW FURNACE PIPE CONNECTOR Central Installation Fig 16 1 U S ONLY Add On Installation COLD AIR DUCT 6 PIPE DAMPER 90 ELBOW FURNACE PIPE CONNECTOR EXISTING GAS OIL ELECTRIC FURNACE 8 PIPE Fig 16 U S ONLY FIGURE 15 1 FIGURE 15 1 ...

Страница 19: ...19 U S ONLY COLD AIR RETURN TO EXISTING DUCT WORK WARM AIR EXISTING FURNACE SOLID FUEL FURNACE FILTER BOX APPENDIX INSTALLATION A ...

Страница 20: ...URN TO EXISTING DUCT WORK WARM AIR EXISTING FURNACE SOLID FUEL FURNACE FILTER BOX PLENUM COLLECTOR BOX COLD AIR RETURN TO EXISTING DUCT WORK WARM AIR EXISTING FURNACE SOLID FUEL FURNACE FILTER BOX PLENUM ELBOW PLENUM TOP OPTIONAL U S ONLY U S ONLY ...

Страница 21: ...N CONTROL LOCATION FURNACE PLENUM EXISTING FURNACE ANTI BACKDRAFT FLAPPER SOLID FUEL FURNACE COLD AIR RETURN INSTALLATION D 2 MINIMUM CLEARANCE DUCT WORK FURNACE PLENUM EXISTING FURNACE SOLID FUEL FURNACE COLD AIR RETURN INSTALLATION E BAFFLE U S ONLY U S ONLY ...

Страница 22: ...ANCE DUCT WORK FURNACE PLENUM EXISTING FURNACE SOLID FUEL FURNACE COLD AIR RETURN INSTALLATION F 2 MINIMUM CLEARANCE DUCT WORK SOLID FUEL FURNACE INSTALLATION G COLD AIR RETURN TO FILTER BOX CENTRAL FURNACE INSTALLATION ...

Страница 23: ...23 2 MINIMUM CLEARANCE EXISTING OIL ELECTRIC OR GAS FURNACE SOLID FUEL FURNACE INSTALLATION H EXISTING OIL ELECTRIC OR GAS FURNACE SOLID FUEL FURNACE TOP VIEW FRONT VIEW ...

Страница 24: ...g See P 14 b Bad blower control b Replace blower control 6 Blower runs too long Blower control cut off set Set blower control cut off to too low higher setting See P 14 7 Blower does not run long a Blower control cut off set a Set blower control cut off to enough too high lower setting See P 14 b Bad blower motor b Replace Blower 8 Smoke and or odor from Oil from furnace and duct The metal used in...

Отзывы: