3

IT IS YOUR OR THE INSTALLER’S RESPONSIBILITY TO READ ALL SAFETY PRECAUTIONS 

AND FOLLOW THE PRESCRIBED DIRECTIONS�

When properly maintained and operated your stove should give you many years of service.  How-

ever there are important safety aspects of these products that you need to be aware of when oper-

ating a wood stove.
1. ONLY USE SOLID WOOD FUEL. NEVER USE GASOLINE, GASOLINE-TYPE LANTERN FUEL, 

KEROSENE, CHARCOAL LIGHTER FLUID, NAPHTHA, ENGINE OIL, OR SIMILAR LIQUIDS 

TO START OR ‘FRESHEN UP’ A FIRE IN THIS STOVE.  KEEP ALL SUCH LIQUIDS WELL 

AWAY FROM THE STOVE WHILE IT IS IN USE.  DO NOT BURN GARBAGE IN THE STOVE.

2. The burning of wood gives off gases which can be extremely dangerous. The stove is designed 

that under normal operating circumstances these gases pass up the flue chimney system and 

cannot escape into your home, however it is important that your flue system is properly installed 

and that you check all joints regularly to ensure that there are no cracks or gaps, check the door 

sealing  rope  and  replace  when  damaged.  We  recommend  a  smoke  alarm  be  fitted  in  rooms 

where stoves are installed. Do not use stove in a room where negative pressure conditions may 

occur, such as through the use of extraction fans unless an adequate air supply into the room is 

ensured, as this may draw air through the stove and cause products of combustion to escape into 

the room.

3. Creosote and soot may accumulate in your flue pipe and chimney. This may ignite, causing a 

chimney fire. If you suspect a chimney fire evacuate people from the building, close down the 

air controls on the stove and call the Fire Department. To prevent the accumulation of soot or 

creosote, check flue and chimney regularly and clean as necessary. Good burning, hot stoves 

will generally cause a lot less build-up than slow burning stoves. Likewise dry wood will cause 

less build-up than wet wood. We recommend a fire extinguisher be available where stoves are 

in operation. In the event of a chimney fire do not re-light the stove until it and the flue chimney 

system have been thoroughly checked and repaired as necessary.

4. Stoves get extremely hot and should not be touched when lit. When young children are in the 

area, we recommend the use of a suitable fire guard around the stove. Always wear protective 

gloves when reloading stove.

5. Never over-fire your stove. If external parts of your stove are glowing red then the stove is over-

firing and your draft settings should be reduced. Never interfere with the draft mechanisms or 

adjust your air settings outside those limits set when the stove is manufactured. Never use a fan 

to supply air to the stove or to extract air from it.

6. All users of the stove should be aware of the contents of this manual. Please leave this manual 

where it is accessible to stove users and do not allow anyone to use the stove that is unfamiliar 

with its correct operation.

7. Never use the stove if any parts are missing or damaged, only use genuine parts as replace-

ments. Never modify your stove.  

8. DO NOT INSTALL IN A MOBILE HOME.

We hope you have many years of warmth and comfort from your stove 

but please do so safely�

Stove Safety

Содержание Brunswick 3800PB

Страница 1: ... Contact local building fire officials or the authority having jurisdiction about restrictions and installation inspection requirements in your area Kindly save these instructions for future reference VERY IMPORTANT PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE YOUR NEW ROOM HEATER FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE BODILY INJURY OR EVEN DEATH FAILURE TO READ ...

Страница 2: ...5 The Floor Protection 5 Installation Clearances 6 Installation Clearances 7 Chimney Connection 7 Chimney 8 Chimney Height 8 Factory Built Chimney 9 Masonry Chimney 10 Combustible Wall Chimney Connector Pass Throughs 11 Operating Your Stove 12 Fuel 12 First operation of stove 12 Air controls 12 Refueling 13 Ash Removal 13 Overnight Burning 13 Stove Maintenance 14 Care of Glass 14 Replacement of Gl...

Страница 3: ...imney fire If you suspect a chimney fire evacuate people from the building close down the air controls on the stove and call the Fire Department To prevent the accumulation of soot or creosote check flue and chimney regularly and clean as necessary Good burning hot stoves will generally cause a lot less build up than slow burning stoves Likewise dry wood will cause less build up than wet wood We r...

Страница 4: ...fficient combustion of the fuel A well sealed flue chimney system herein after referred to as the flue system The protection of combustible materials in proximity of the stove It is essential for the safe and efficient use of your stove that you provide an adequate air supply to your stove This may mean the provision of an outside air supply to the room especially if there are extraction units suc...

Страница 5: ...aler immediately and we will rectify the situation 4 Gently lay the stove on its back Remove screws from 4 corners of base and fit one of the legs to each corner of the stove Tighten bolt to ensure leg is secure to base of stove When complete gently stand the stove upright 5 Move the stove into position Do not drag the stove as this may damage the legs screws or base Installation If the stove is t...

Страница 6: ...al that can catch fire A combustible surface is anything that can burn i e sheet rock wall paper wood fabrics etc These surfaces are not limited to those that are visible and also include materials that are behind non combustible materials If you are not sure of the combustible nature of a material consult your local fire officials Installation Clearances 3600PB Single Wall Connector Pipe 3800PB S...

Страница 7: ...erials of the house It is also essential that the flue system is kept clean and seals are maintained to ensure the draft is not lost The open end of the flue system must be above the height of the apex of the building and any other obstructions such as trees which are within 3 meters 10ft of the flue system Failure to do this will affect the efficiency of the stove and may cause down drafts which ...

Страница 8: ...f the chimney connectors must be accessible for cleaning Where passage through a wall or partition of combustible construction is desired the installation must conform with NFPA 211 or CAN CSA B365 and is also addressed in this manual DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM This room heater must be connected to a 6 ...

Страница 9: ...nstall the ceiling support package or wall pass through and T section package firestops where needed insulation shield roof flashing chimney cap etc Maintain proper clearance to the structure as recommended by the manufacturer The chimney must be the required height above the roof or other obstructions for safety and proper draft operation Factory Built Chimney ...

Страница 10: ...y having it inspected by a professional Make sure there are no cracks loose mortar or other signs of deterioration and blockage Have the chimney cleaned before the stove is installed and operated When connecting the stove through a combustible wall to a masonry chim ney special methods are needed Masonry Chimney ...

Страница 11: ...himney connector and a minimum 24 gage ventilated wall thimble which has two air channels of 1 25 4 mm each construct a wall pass through There shall be a minimum 6 152 4 mm sep aration area containing fiberglass insulation from the outer surface of the wall thimble to wall combustibles Support the wall thimble and cover its opening with a 24 gage minimum sheet metal sup port Maintain the 6 152 4 ...

Страница 12: ...t progressively bigger We recom mend a series of about five small fires before you put the stove into full service Allow the stove to fully cool between each of these fires There may be some smell and a small amount of smoke from the stove during the initial operations This is perfectly normal and is merely the curing of the stove paint Opening a window or door to provide additional ventilation wi...

Страница 13: ... If possible this should be done before lighting the stove when the ash is cold Even if the ash appears to be cold it should be placed in a non combustible container as there may be hot ash in the center of the pile You should always were protective gloves when removing ash from the stove Overnight Burning This stove is not designed to operate with the door open Always close the stove door when yo...

Страница 14: ...ints To check flue outlet remove top of baffle by lifting and pulling out at end Use a flashlight to check flue out let Clean and repair as necessary Always replace top baffle before relighting stove 2 Check that glass is not cracked or chipped and that sealing rope is in good condition Replace as necessary 3 When the room is dark use a strong flashlight to check the sealing of the stove at the ed...

Страница 15: ...an be re painted by using a good quality high temperature stove paint When re painting make sure there is plenty of ventilation and follow the manufacturer s instructions Allow the paint to fully dry before lighting the stove and allow extra ventilation for the first couple of fires as some fumes may emit from the stove as the paint cures Surface Finish A stove not burning is generally caused by e...

Страница 16: ...your flue system You should not install a flue damper without con sulting a specialist Never install a damper that can completely block your flue or chimney Contact your dealer to discuss this Fire Burns too Quickly Chimney fires occur when soot and creosote that have built up in the flue system ignite If the stove is operated properly and the flue checked and cleaned regularly then chimney fires ...

Страница 17: ...e paint gaskets burn plates baffles fire grates or glass glass is only warranted against thermal breakage 2 Damage due to incorrect installations not in conformance with the manufacturer s installation instructions or local and national regulations It is the responsibility of the installer to ensure that the unit is installed and operating correctly at the time of installation 3 Damage caused by o...

Страница 18: ...F517U 16 1 17 891694 Back Plate Ornamental HF517U 17 1 18 40528 Back Cover HF517U 18 1 19 40529 Cover Back Air Inlet HF517U 19 1 20 40530 Lock tight Piece HF517U 20 1 21 40531 Back HF517U 21 1 KEY PART DESCRIPTION QTY 22 891695 Slide Plate Holding Frame HF517U 22 1 23 891696 Slide Plate HF517U 23 1 24 891697 Glass Holding Frame HF517U 24 4 25 891698 Glass HF517U 25 1 26 40532 Grate HF517U 26 1 27 ...

Страница 19: ...7 891723 Ashpan HF717U 18 1 18 40549 Spin Valve HF717U 19 1 19 40550 Operating Tool HF717U 20 1 20 40551 Ash Door HF717U 21 1 21 891724 Handle Pays HF717U 22 22 891725 Door Latch Plate HF717U 25 1 KEY PART DESCRIPTION QTY 23 891726 Door Handle HF717U 26 1 24 891727 Door Catch HF717U 27 1 25 40552 Fire Door HF717U 28 1 26 40553 Fire Fence Bracket HF717U 31 2 27 40554 Door Catch Sealing Plate HF717U...

Страница 20: ...WHICH IS ON THE NAMEPLATE ATTACHED TO THE HEATER WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION AS SHOWN IN THIS LIST 1 THE PART NUMBER 2 THE PART DESCRIPTION 3 THE MODEL NUMBER 3600PB 3800PB 4 THE SERIAL NUMBER ____________________ How to order repair parts United States Stove Company 227 Industrial Park Road P O Box 151 South Pittsburg TN 37380 800 750 2723 WWW USSTOVE COM C S ...