USSC 1869 Скачать руководство пользователя страница 8

8

© 2021 United States Stove Company

ASSEMBLY & INSTALLATION

WARNING:

NEVER OPERATE THIS HEATER WITH THE FUEL 

DOOR OPEN.

WARNING:

DO NOT OBSTRUCT THE SPACE BENEATH THE 

HEATER

SERVICE HINTS

Do not expect a heater to draw. It is the chimney that 

creates the draft. Smoke spillage into the house or 

excessive buildup of water or creosote in the chimney are 

warnings that the chimney is not functioning properly. 

Correct problem before using heater. Possible causes are:
1.  The connector pipe may push into the chimney too 

far, stopping the draft.

2.  Do not connect two heaters into the same chimney 

flue.

3.  The chimney used for a heater must not be used to 

ventilate the cellar or basement. If there is a cleanout 

opening at the base of the chimney, It must be closed 

tightly.

4.  If the chimney is operating too cool, water will 

condense in the chimney and run back into the 

stove. Soot formation will be rapid and may block 

the chimney. Operate the heater at a high enough 

fire to keep the chimney warm preventing this 

condensation.

If the fire burns well but sometimes smokes or burns 

slowly, it may be caused by the chimney top being lower 

than another part of the house or a nearby tree. The wind 

blowing over a house or tree, falls on top of the chimney 

like water over a dam, beating down the smoke. The top 

of the chimney should be at least 3 feet above the roof 

and be at least to 2 feet higher than any point of the roof 

within 10 feet.

CREOSOTE - FORMATION & NEED FOR 

REMOVAL

When solid fuel is burned slowly, it produces tar and other 

organic vapors, which combine with expelled moisture 

to form creosote. The creosote vapors condense in the 

relatively cool chimney flue of a slow burning fire. As a 

result, creosote residue accumulates on the flue lining. 

When ignited, this creosote makes an extremely hot fire. 

The chimney connector and chimney should be inspected 

at least twice monthly during the heating season to 

determine if a creosote or soot buildup has occurred. If 

there is any accumulation, it should be removed. Failure 

to remove creosote may cause a house fire. Soot may be 

removed by using a chimney brush or other commonly 

available materials. Chimney fires burn very hot. If the 

chimney connector should glow red, immediately call the 

fire department, then reduce the fire by closing the inlet 

air control and pour a large quantity of coarse salt, baking 

soda or cool ashes on top of the fire in the firebox.

CAUTION:

A CHIMNEY FIRE MAY CAUSE IGNITION OF WALL 

STUDS OR RAFTERS WHICH YOU THOUGHT WERE 

A SAFE DISTANCE FROM THE CHIMNEY. IF YOU 

HAVE A CHIMNEY FIRE, HAVE YOUR CHIMNEY 

INSPECTED BY A QUALIFIED PERSON BEFORE 

USING AGAIN.

CAUTION:

DO NOT TOUCH THE HEATER UNTIL IT HAS 

COOLED.

NOTE:

FOR YOUR SAFETY, WE RECOMMEND INSTALLING 

SMOKE DETECTORS IN YOUR HOME IF NOT 

ALREADY INSTALLED.

Содержание 1869

Страница 1: ... NEVER OPERATE THIS PRODUCT WHILE UNATTENDED CAUTION Please read this entire manual before you install or use your new room heater Failure to follow instructions may result in property damage bodily injury or even death Improper Installation Will Void Your Warranty Save These Instructions In A Safe Place For Future Reference CALIFORNIAPROPOSITION65WARNING This product can expose you to chemicals i...

Страница 2: ...x Capacity 40 lbs Firebox Depth 10 Flue Size 6 Door Opening 8 x 10 Material 100 Cast Iron Fuel Coal NOTE Bituminous large nut to small egg or Anthracite large egg to small broken BTU Rating 80 000 Weight 168 lbs 15 FLOOR PROTECTOR 19 1 2 36 SAFETY NOTICE IF THIS HEATER IS NOT PROPERLY INSTALLED A HOUSE FIRE MAY RESULT FOR YOUR SAFETY FOLLOW THE INSTALLATION DIRECTIONS CONTACT LOCAL BUILDING OR FIR...

Страница 3: ..._______________________________________ If no Date of inspection of the existing chimney system ___________________________________________________________ COMMISSIONING Confirm hearth pad installation as per installation instructions Confirm proper placement of internal parts Check soundness of door gasket and door seals Confirm clearances to combustibles as per installation instructions in this ...

Страница 4: ... where the stove is located If the intake is not in the same room air must have free access to the room 8 To prevent injury do not allow anyone to use this stove who is unfamiliar with the correct operation of the stove 9 Dispose of the ashes in a metal container with a tight fitting lid Keep the closed container on a non combustible floor or on the ground well away from all combustible materials ...

Страница 5: ...ply with UL Standards The base should extend at least 18 beyond the door side of the heater and should extend under the flue pipe if it is elbowed towards a wall After observing the clearances to combustibles locate your floor protector accordingly and carefully place the stove in your selected location Install stovepipe elbows and thimble as necessary utilizing either a recently cleaned and inspe...

Страница 6: ...MASONRY CHIMNEY ThemasonrychimneymustcomplywithULcodes Before using an existing masonry chimney clean the chimney and inspect the flue liner to be sure it is safe to use Make repairs before attaching the heater The connector pipe and fittings you will need to connect directly to a masonry chimney are shown If the connector pipe must go through a combustible wall before entering the masonry chimney...

Страница 7: ... keep spin damper on feed door closed 2 Burn coal only Use wood for coal ignition purposes only Build six 6 small fires upon initial firing Light wood using paper twigs etc 3 After the fire has been started and is burning satisfactorily close slide draft almost all the way 4 Open adjustspindraftonfeeddoortoallowadditional air into the stove on top of the fire This will allow a more efficient burn ...

Страница 8: ...e top of the chimney should be at least 3 feet above the roof and be at least to 2 feet higher than any point of the roof within 10 feet CREOSOTE FORMATION NEED FOR REMOVAL When solid fuel is burned slowly it produces tar and other organic vapors which combine with expelled moisture to form creosote The creosote vapors condense in the relatively cool chimney flue of a slow burning fire As a result...

Страница 9: ...ELL ESTABLISHED add coal to the center of the firebox forming the cone Burning in this fashion allows heat to drive off the volatile gases and turbulence created increases the burn efficiency There will have to be some experimenting with the individual setup as no two chimney s or installations are going to be the same Just remember to allow enough air to enter the firebox and keep the stove pipe ...

Страница 10: ...during this time After loading let the fire establish itself for about 30 minutes Then close your damper and automatic control to the point where the house does not become too cold It is important that you begin banking early enough before retiring or leaving that you can make necessary adjustments after the fire is well established To revive a coal fire that is almost out 1 open the ash door and ...

Страница 11: ...ENTS WILL VOID THE WARRANTY Key Part Description Qty 1 89979 Top Plate 1 2 89980 Upper Chamber 1 3 89981 Feed Chamber 1 4 89982 Burn Chamber 1 5 89983 Lower Chamber 1 6 89984 Base 1 7 89985 Legs 4 8 89987 Slide Draft 1 9 89988 Slide Draft Knob 1 10 89986 Ash Door 1 11 89992 Spin Draft 1 12 89991 Feed Door 1 13 89994 Cook Lid 1 14 89993 Collar Top 1 89989 Shaker Grate 1 89990 Spring Handle 1 NOT SH...

Страница 12: ...______ Engineer Name _____________________________________ License No _________________________________________ Company ___________________________________________ Telephone No ______________________________________ Stove Inspected Chimney Swept Items Replaced _____________________________________ Service 02 Date _______________________ Engineer Name _____________________________________ License N...

Отзывы: