9
To test briefly, you can connect the module with computer via network cable, or you can also
connect the module and computer to switch or router at the same time. No need to distinguish
cross and direct connect cable, the module have automatic switch function, and, change
computer IP to 192.168.0. *, such as 192.168.0.201 we test.
Connect the module serial to computer through cross serial cable. If you use RS232 to USB
turn wiring. Please pay attention to the quality of the turn wiring, most low price USB turn
RS232 cable on market is low quality at present
Power up, voltage range 5~18V.
计 算 机
计 算 机
计 算 机
计 算 机
网
线
R S
2 3
2串
口
Login above IP address
http://192.168.0.7
http://192.168.0.7
http://192.168.0.7
http://192.168.0.7
through the browser, you will enter setup web
pages.
User name and password are “ admin ”, this can be modified when login into the system.