Страница 1: ...POWER EV10i POWER...

Страница 2: ...OWNER S MANUAL USR EV10i The e SPEC mark symbolizes environmentally responsible technologies applied to USR power equipment which contains our wish to preserve nature for generations to come...

Страница 3: ...ion and maintenance of the EV10i generator All information in this publication is based on the latest product information available at the time of approval for printing We reserves the right to make c...

Страница 4: ...s 8 COMPONENT IDENTIFICATION 9 PRE OPERATION CHECK 13 STARTING THE ENGINE 18 Carburetor Modification for High Altitude Operation GENERATOR USE 22 STOPPING THE ENGINE 34 MAINTENANCE 36 TRANSPORTING STO...

Страница 5: ...ng the generator indoors Exhaust gas contains poisonous carbon monoxide Never run the generator in an enclosed area Be sure to provide adequate ventilation When installed inside adequate ventilation s...

Страница 6: ...ped Connections for standby power to a building s electrical system must be made by a qualified electrician and must comply with all applicable laws and electrical codes Improper connections can allow...

Страница 7: ...is tilted fuel spillage may result Keep children and pets away from the generator when it is in operation Keep away from rotating parts while the generator is running The generator is a potential sou...

Страница 8: ...HAUST CAUTION For European model G GW B F W types These labels warn you of potential hazards that can cause serious injury Read the labels and safety notes and precautions described in this manual car...

Страница 9: ...7 For Australian model U type SOCKET CAUTION...

Страница 10: ...ISE LABEL Maximum altitude IP code Performance class Maximum ambient temperature CE mark and noise label locations CE MARK For European model G GW B F W types Model EV10i Inverter Generator EV10i Inve...

Страница 11: ...EL FILLER CAP CONTROL PANEL FRAME SERIAL NUMBER ENGINE SWITCH LEFT SIDE MAINTENANCE COVER MUFFLER SPARK PLUG MAINTENANCE COVER STARTER GRIP Record the frame serial number in the space below You will n...

Страница 12: ...CUIT PROTECTOR DC RECEPTACLE OIL ALERT INDICATOR LIGHT ECO THROTTLE SWITCH OUTPUT INDICATOR LIGHT OVERLOAD INDICATOR LIGHT GROUND TERMINAL AC RECEPTACLE PARALLEL OPERATION SOCKETS CONTROL PANEL G GW F...

Страница 13: ...11 AC RECEPTACLE AC RECEPTACLE B type U type...

Страница 14: ...tion is recommended to minimize the fuel consumption while in operation Eco Throttle system does not operate Engine speed is kept over rated speed Eco Throttle system does not operate sufficiently if...

Страница 15: ...could shorten the engine service life SAE Viscosity Grades AMBIENT TEMPERATURE Check the engine oil level Use high detergent premium quality 4 stroke engine oil certified to meet or exceed U S automob...

Страница 16: ...ith a clean rag Check the oil level by inserting the dipstick in the filler hole without screwing it in If the oil level is below the end of the dipstick refill with recommended oil up to the top of t...

Страница 17: ...ntilated area with the engine stopped Do not smoke or allow flames or sparks in the area where the engine is refueled or where gasoline is stored Gasoline is extremely flammable and is explosive under...

Страница 18: ...es not also contain cosolvents and corrosion inhibitors for methanol Never use gasoline containing more than 5 methanol even if it has cosolvents and corrosion inhibitors If you decide to use a gasoli...

Страница 19: ...NT AIR CLEANER BODY LOWER TAB LEFT SIDE MAINTENANCE COVER AIR CLEANER COVER LATCH TAB Check the air cleaner Check the air cleaner element to be sure it is clean and in good condition Loosen the cover...

Страница 20: ...NE SWITCH Before starting the engine disconnect any load from the AC receptacle Turn the fuel cap vent lever to the OFF position when transporting the generator Turn the engine switch to the ON positi...

Страница 21: ...CLOSED STARTER GRIP CHOKE LEVER Do not use the choke when the engine is warm or the air temperature is high Pull the starter grip lightly until you feel resistance then pull the starter grip briskly t...

Страница 22: ...HOKE LEVER O OP PE EN N Move the choke lever to the OPEN position as the engine warms up If the engine stops and will not restart check the engine oil level see page before troubleshooting in other ar...

Страница 23: ...ve your authorized servicing dealer perform this carburetor modification This engine when operated at high altitude with the carburetor modifications for high altitude use will meet each emission stan...

Страница 24: ...proper connections can allow electrical current from the generator to backfeed into the utility lines Such backfeed may electrocute utility company workers or others who contact the lines during a pow...

Страница 25: ...oth at the same time be sure not to exceed the total power for AC and DC See page The DC receptacle can be used while the AC power is in use Most appliance motors require more than their rated wattage...

Страница 26: ...amine it for signs of malfunction Substantial overloading that continuously lights the overload indicator light red may damage the generator Marginal overloading that temporarily lights the overload i...

Страница 27: ...if the Overload indicator red goes off after about five 5 seconds If the Overload indicator red stays on consult your generator dealer If the generator is overloaded in excess of 1 0 kVA or if there i...

Страница 28: ...peration is Maximum power in parallel operation is 1 8 kVA 2 0 kVA Please read the item GENERATOR USE before connecting any equipment to be used A max output of 2 0 kVA can be obtained by using two un...

Страница 29: ...ecial cable for parallel operation must be removed UNIT UNIT SPECIAL CABLE FOR PARALLEL OPERATION SOLD SEPARATELY Depending on the equipment to be used an overload may be caused the overload indicator...

Страница 30: ...MINAL Start each engine according to STARTING THE ENGINE When the output indicator light green does not light and the overload indicator light red lights instead set the engine switch to STOP stop the...

Страница 31: ...dicator light green will light At this time the engine will not stop so that the engine must be stopped by setting the respective engine switch to STOP In case of overload operation refer to page or w...

Страница 32: ...go out and the output indicator light green will stay lit When the operation of one generator is to be stopped after start of the equipment the special cable for parallel operation also must be remov...

Страница 33: ...if you make accidental contact between a battery terminal and the vehicle frame or body Do not attempt to start an automobile engine with the generator still connected to the battery The generator may...

Страница 34: ...Internal Drink large quantities of water or milk Follow with milk of magnesia or vegetable oil and call a physician immediately CHEMICAL HAZARD Battery electrolyte contains sulfuric acid Contact with...

Страница 35: ...ore the oil level in the crankcase falls below a safe limit the Oil Alert system will automatically shut down the engine the engine switch will remain in the ON position If the Oil Alert system shuts...

Страница 36: ...N NORMAL USE OFF ENGINE SWITCH OFF PLUG To stop the engine in an emergency turn the engine switch to the OFF position Switch off the connected equipment and pull the inserted plug Turn the engine swit...

Страница 37: ...sporting and or storing the generator OFF OFF FUEL CAP VENT LEVER SPECIAL CABLE FOR PARALLEL OPERATION SOLD SEPARATERY Turn the fuel cap vent lever fully counterclockwise to the OFF position When para...

Страница 38: ...cated month or operating hour interval whichever comes first Each use Every 3 months or 50 hrs 1 Engine oil Air cleaner Spark plug Spark arrester Valve Clearance Combustion chamber Fuel tank filter Fu...

Страница 39: ...service station for reclamation Do not throw it in the trash or pour it on the ground Wash your hands with soap and water after handling used oil Reinstall the left side maintenance cover and tighten...

Страница 40: ...the air cleaner regularly Service more frequently when operating the generator in extremely dusty areas Loosen the cover screw and remove the left side maintenance cover Press the latch tab on the top...

Страница 41: ...NANCE COVER To ensure proper engine operation the spark plug must be properly gapped and free of deposits Remove the spark plug cap Clean any dirt from around the spark plug base Use a spark plug wren...

Страница 42: ...reused Measure the plug gap with a feeler gauge Correct as necessary by carefully bending the side electrode The gap should be After a new spark plug has been seated by hand it should be tightened 1...

Страница 43: ...been running the muffler will be very hot Allow it to cool before proceeding 4 Equipped type 6 mm BOLTS MUFFLER PROTECTOR 5 mm SCREW MUFFLER GASKET SPARK ARRESTER MUFFLER Remove the three 6 mm bolts...

Страница 44: ...arrester screen Inspect the spark arrester screen for holes or tears Replace if necessary Check the muffler gasket replace if damaged Reinstall the muffler gasket the spark arrester the muffler and th...

Страница 45: ...e Do not overfill the tank there should be no fuel in the filler neck When transporting the generator Gasoline is extremely flammable and is explosive under certain conditions Perform this task in a w...

Страница 46: ...ten the drain screw securely Reinstall the spark plug cap on the spark plug securely Change the engine oil Remove the spark plug and pour about a tablespoon of clean engine oil into the cylinder Crank...

Страница 47: ...enough oil in the engine Is the engine switch on Turn the engine switch on Add the recommended oil Is the spark plug in good condition Clean readjust gap and dry the spark plug Replace it if necessary...

Страница 48: ...cuit protector on Take the generator to an authorized dealer Is the Overload indicator ON Check the electrical appliance or equipment for any defects Take the generator to an authorized dealer Replace...

Страница 49: ...erhead valve single cylinder 50 cm 3 1 cu in 41 8 36 0 mm 1 64 in 1 42 in 8 0 1 Forced air Full transistor 0 25 0 26 US qt 0 22 Imp qt EV10i 5 500 rpm with eco throttle switch OFF 2 3 0 61 US gal 0 51...

Страница 50: ...dB 87 dB Model Type Sound pressure level Lp According to 98 37 EC Guaranteed sound power level L Tested by 2000 14 EC Model Type AC output DC rated output Only for charging 12 V automotive batteries 1...

Страница 51: ...gine Ground Engine Switch Exciter Winding Frame Block Frame Ground Generator Block Ground Terminal Ignition Coil Inverter Unit Main Winding Oil Alert Indicator Overload Indicator Oil Level Switch Puls...

Страница 52: ...50 BLACK YELLOW BLUE GREEN RED WHITE BROWN LIGHT GREEN GRAY LIGHT BLUE ORANGE PINK Bl Y Bu G R W Br Lg Gr Lb O P ECOTHROTTLE SWITCH ENGINE SWITCH OFF ON OFF ON G Bl R W R Y ECO OFF ON...

Страница 53: ...51 G GW B F W type...

Страница 54: ...52 U type...

Страница 55: ...53 RECEPTACLE Shape Type B W F U G GW...