3.2. Hardware Reference Design
3.2.1. Typical Application Connection
Diagram 3.2.1-1
Typical Application Connection
Note:
1)
RST: Restart button. It works at low level, 3.3V, 10K pull-up resistor inside. When it access to power or
breakdown, pull down 300ms then high level.
2)
Link: connection indication.Can be used as indication pin for net connection, when connected, it outputs low
level; When unconnected, it output high level.
3)
CFG(Reload): connect to external button or configuration pin. 3.3V, 10K pull-up resistor inside. Press it
and pull to low level, then release hands after 3 seconds, module restores factory default and restart.
4)
UART_TXD/RXD: data rend/ receive signal(10K pull-up resistor inside)
3.2.2. Power Interface
USR-TCP232-T2 has dual power supply interface, 5.5 v and 3.3 v (only choose one) Working current 150 mA, max
current 200mA .
VCC: typical value DC 3.3V, 3.15V~3.45 V. It is used for 3.3 V MCU.
VDD: typical value DC 5V, 4.75V~5.5V. When connect to 5V MUC, refer to Diagram 3.2.3 -2 3.3V to 5V voltage
conversion circuit