Multifunctional serial to Ethernet module user manual
www.usriot.com
Jinan USR IOT Technology Co., Ltd
Page35
////
9
If there is no data since the last char received during the past 10ms, the current data will be
send to remote server.
If the currently received data length exceed 512 byte, then the module will pack all the 512
byte and send to remote server.
The pack mechanism would be triggered if there is either 1 condition meet them.
If we set packet time and packet length to 0, then the module would use a mechanism of
auto-packet, which have 4-byte-time packet time, and 1460 byte packet length(available only
when firmware revision >= 3006).
6.5.
6.5.
6.5.
6.5. Sync
Sync
Sync
Sync baud
baud
baud
baud via
via
via
via net(2217)
net(2217)
net(2217)
net(2217)
This is a function similiar to RFC2217(but different protocol), which can modify the device's
comm parameters via ethernet(tcp or udp connection).
This option is checked by default.
Diagram 6-5 sync baud