USR IOT USR-M511 Скачать руководство пользователя страница 15

                                                  USR-M511User Manual                                Technical Support: 

h.usriot.com

   

 

Jinan USR IOT Technology Limited                                                                                                                                     

www.usriot.com

 

 

15

 

 

Figure 18 Modbus slave mark configuration

 

(3)Refresh Modbus Management and query the data. Web server will update data value without refreshing. 

 

2.4.2.Modbus data management 

M511  support  Modbus  data  management  function  to  query  Slave  information  through  Modbus  Management 
web-page.  When  user  open  Modbus  data  management  function,  M511  will  disable  querying  commands  from 
Modbus Master to Modbus Slave(close protocol conversion function). 
 
User can configure Modbus data management as follow: 

 

Figure 19 Modbus data management configuration

 

Содержание USR-M511

Страница 1: ...USR M511User Manual Technical Support h usriot com Jinan USR IOT Technology Limited 1 USR M511 User Manual File Version V1 0 4 01...

Страница 2: ...lt settings 9 2 1 3 Upgrade Firmware Version 9 2 2 Serial port 10 2 2 1 Serial Port Basic Parameter 10 2 2 2 Serial Package Methods 11 2 2 3 Baud Rate Synchronization 11 2 3 Modbus protocol transmissi...

Страница 3: ...I_Slave work modes Support Modbus Master Prefetch function Support 8 Modbus Slave automatic query by commands Support Modbus web server management function 10 100Mbps Ethernet interface support Auto M...

Страница 4: ...ted www usriot com 4 1 Get Start Product link http www usriot com p industrial modbus gateway modbus rtuascii modbus tcp Figure 1 Download Page If you have any question please submit it back to custom...

Страница 5: ...USR M511User Manual Technical Support h usriot com Jinan USR IOT Technology Limited www usriot com 5 1 2 Hardware Design 1 2 1 Hardware Dimensions Figure 3 Hardware dimensions...

Страница 6: ...Off Not working TX On Sending data to serial Off No data sending to serial RX On Receiving data from serial Off No data receiving from serial Figure 4 Hardware Indicator 1 2 3 DB9 Pin definition Pin N...

Страница 7: ...USR M511User Manual Technical Support h usriot com Jinan USR IOT Technology Limited www usriot com 7 Type 1 2 3 4 5 RS232 TX RX GND RS485 A B GND RS422 T T R R GND Figure 6 DB9 pinboard...

Страница 8: ...ically querying by commands on network side Sending read write commands 1 1 1 Protocol Conversion 1 1 1 Identity packet USR Cloud 1 Modbus storing and dispatching 1 Modbus Slave status dispalying Figu...

Страница 9: ...IP DHCP 2 1 2 Hardware Restore default settings User can press Reload over 5s and less than 15s then release to restore default settings 2 1 3 Upgrade Firmware Version User can contact to salespersons...

Страница 10: ...parameters as follow Parameter Default Range Baud rate 115200 600 230400bps Data bits 8 5 8 Parity None None Odd Even Mark Space Stop bits 1 1 2 Flow control None None No flow control HardWare Hardwa...

Страница 11: ...us_RTU_Master Modbus_ASCII_Master Modbus_RTU_Slave Modbus_ASCII_ Slave Work mode can be defined according to the serial port device of M511 and Modbus protocol For example serial port device is Modbus...

Страница 12: ...so querying command with ID 2 will be send to this slave G Enable SocketB Enable socket B to set salve 2 parameters H Timeout Reconnection No data transmission over this time M511 will automatically d...

Страница 13: ...can change Modbus Slave mode parameters by web server as follow Figure 15 Modbus Slave mode configuration A Work mode Four types work modes B Enable Modbus Over TCP IP Open this function M511 will wo...

Страница 14: ...o user need use browser which can support Websocket as follow Browser Version Chrome Version 4 Firefox Version 4 Internet Explorer Version 10 Opera Version 10 Safari Version 5 Figure 16 Browser versio...

Страница 15: ...ta value without refreshing 2 4 2 Modbus data management M511 support Modbus data management function to query Slave information through Modbus Management web page When user open Modbus data managemen...

Страница 16: ...Features 2 5 1 Network Identity Packet Function M511 work in Modbus Master mode can send identity packet to Slave Identity packet can be user editable data or MAC address Identity packet will be sent...

Страница 17: ...rt and enter web server to configure Web server default parameters as follow Parameter Default settings Web server IP address 192 168 0 7 User name admin Password admin Figure 21 Web server default pa...

Страница 18: ...d AT command to module For entering AT command mode please refer to this FAQ http www usriot com enter serial command mode 3 2 2 Network AT Command Network AT command is to send a search keyword by br...

Страница 19: ...mation of USR M511 products it hasn t been granted any intellectual property license by forbidding speak or other ways either explicitly or implicitly Except the duty declared in sales terms and condi...