34
Diagram 2-5 default working mode communication
Chart 1 default parameters
project
content
User name
admin
Password
admin
IP address
192.168.0.7
K7 subnet mask
255.255.255.0
K7 default gateway
192.168.0.1
K7 port1 default mode
TCP Server
K7port1 default interface
23
Serial port baud rate
115200
Serial port parameters
None/8/1
Diagram 2-6 Default parameters
2.4.
Data transmission text
After above steps, you can do bi-communication between serial port and Ethernet. Step are
as follows:
1)
Open the ‘USR-TCP232-Test.exe’, connect the hardware.
2)
Choose the TCP Client mode in net setting, put in 192.168.0.7 in server IP address, and the port
number is 23. Click connection to built TCP link. Serial port baud rate is 115200, serial port
parameters is None/8/1, then click OPEN to open the serial port.
Now we can text the data transmit between serial port and network. The data flow from serial
port to network is: computer serial port ->K7 serial port ->K7 Ethernet port -> computer network;