USR-G786-G User Manual
Technical Support:
Jinan USR IOT Technology Limited
www.pusr.com
24
1. Open the setup software. Setting the serial port parameters according to the serial device and click "Open
PC Serial".
2. Click "Enter Serial AT command mode" and wait for the device to enter AT command mode.
3. Click "Query all parameters" and waiting for obtaining all current parameters.
4. In "choose work Mode" , select "SMS Mode".
5. Set the destination phone number to "10086".
6. If need to filter SMS from other mobile numbers, enable "Only receive SMS from source number".
7. Click “More”.
8. Set APN parameter: CMNET,,,0.
E.g: APN: CMNET, username:empty, password:empty, authentication method: NONE.
9. Click "Save current parameters" to set and save all parameters.
10.
Click "Restart" to restart the module
.
2
Set by AT command:
1. Set work mode to SMS mode
:
AT+WKMOD=SMS
2. Set the target mobile phone number to 10086. E.g:10086
:
AT+DSTNUM=10086
3.
Restart the module
:
AT+Z