USR-G760c User Manual
h.usriot.com
Jinan USR IOT Technology Limited
/ 37
www.usriot.com
23
31, equal to or greater than -75 dBm
99, unknown or unpredictable
ber: (bit error rate percentage), don’t support BER query at present, will respond 99 in Execution
command and Test command
4.4.10. AT+RELD
Function: Reload to user default settings, device will restart
Format:
Execute specified function
AT+RELD{CR}
{CR}{LF}OK{CR}{LF}
4.4.11. AT+CLEAR
Function: Reload to factory defaults, device will restart
Format:
Execute specified function
AT+CLEAR{CR}
{CR}{LF}OK{CR}{LF}
4.4.12. AT+CFGTF
Function: Save current operation parameters to be default settings
Format:
Execute specified function:
AT+CFGTF{CR}
{CR}{LF}OK{CR}{LF}
4.4.13. AT+VER
Function: Query firmware version
Format:
Query current parameter values:
AT+VER{CR} or AT+VER?{CR}
{CR}{LF}+VER:version{CR}{LF}{CR}{LF}OK{CR}{LF}
Parameters:
version: firmware version number
4.4.14. AT+SN
Function: Query SN code
Format: