NEVER use an open flame of any kind to test this unit. You might accidentally damage or set
fire to the unit or to your home. The built-in test switch accurately tests the unit's operation as
required by Underwriters Laboratories Inc. (UL).

If you choose to use an aerosol smoke product to test the smoke alarm, be certain to use one
that has been Listed to Underwriters Laboratories, Inc. Safety Standards and use it only as
directed. Use of non-UL Listed products or improper use of UL Listed products may affect
the smoke alarm's sensitivity.

Before using the alarm "test/silence" feature, identify the source of smoke or CO and be
certain that safe conditions exist.

FALSE ALARMS "TEST/SILENCE" CONTROL: Units with the "silence" feature have the capability
of temporarily reducing the sensitivity of the smoke alarm circuit for approximately 3-9 minutes. This
feature is to be used only when a known alarm condition such as smoke from cooking activates the
smoke alarm. The smoke alarm "silence" feature is activated by pushing the Test/Silence button on
the smoke alarm cover for at least three seconds. The smoke alarm will automatically reduce sensitivity
and the Red LED will light for approximately 3-9 minutes to indicate the alarm is in the temporary
silent condition. The smoke alarm will gradually regain normal sensitivity and sound the alarm if
particles of combustion are still present. The "silence" feature may be used repeatedly until the air
has cleared.

When AC power is lost, the Green LED is off and flashes on approximately every 40 seconds.

ELECTRICAL SHOCK HAZARD: Turn off power at main service panel by removing fuse or
switching appropriate circuit breaker to OFF position before replacing battery or cleaning
smoke and CO alarm.

MAINTENANCE: This combination alarm is virtually maintenance free. However, under dusty
conditions, a vacuum hose may be used to clear the sensing chamber of dust.

Clean the alarm at least once a month to remove dust, dirt or debris. Always turn off power to
alarm before cleaning. Using a soft brush or wand attachment to a vacuum cleaner, vacuum all
sides and cover of alarm. Be sure all the vents are free of debris.

The outside of the alarm can be wiped with a damp cloth. Do not use any household cleaning
agents, ammonia-based cleaners, paints, varnishes or any other chemical on or near your alarm.
AFTER CLEANING, REINSTALL YOUR ALARM. TEST YOUR ALARM BY USING THE TEST
BUTTON.

If the smoke/CO alarm is false alarming or indicating service and cannot be restored to normal
operation, the alarm should be replaced.

Page 9

Содержание USI-7795

Страница 1: ...ction in case of an AC power failure or a dead battery CO ALARMS are designed to detect carbon monoxide gas from any source of combustion that reaches their sensor They are NOT designed to detect any...

Страница 2: ...ling for assistance Young children and household pets may be the first affected Your combination smoke CO alarm is designed to detect the toxic CO fumes that result from incomplete combustion such as...

Страница 3: ...ready to slam it shut if heat and smoke rush in o Stay close to the floor if air is smoky Breathe shallowly through a cloth wet if possible o Once outside go to your selected meeting place and make su...

Страница 4: ...tion smoke CO alarm should be centrally located outside of each separate sleeping area in the immediate vicinity of the bedrooms Where bedrooms are separated and audibility of the alarm to occupants w...

Страница 5: ...Install at least 3 feet 0 9 meters away from these areas in extremely dusty dirty or insect infested areas Loose particles interfere with smoke alarm operation in areas where temperature may fall bel...

Страница 6: ...C 60Hz circuit Be sure the circuit cannot be turned off by a switch dimmer or ground fault circuit interrupter Failure to connect this unit to a 24 hour circuit may prevent it from providing constant...

Страница 7: ...terconnected CO alarms will only respond if a CO alarm event initiates the alarm All other alarms remain silent NOTE Relay modules USI 960 will not respond if a CO alarm event initiates the alarm Inte...

Страница 8: ...f for proper operation of BOTH the SMOKE and CO detection and alarm circuits The Red LED will begin to flash rapidly and the alarm will indicate two cycles of the SMOKE alarm pattern The Red LED will...

Страница 9: ...or approximately 3 9 minutes to indicate the alarm is in the temporary silent condition The smoke alarm will gradually regain normal sensitivity and sound the alarm if particles of combustion are stil...

Страница 10: ...power before changing battery Shock hazard exists if AC power is miswired This alarm uses a 9 Volt Alkaline battery The battery should last for at least one year under normal operating conditions The...

Страница 11: ...USI ELECTRIC INC at 7 A Gwynns Mill Court Owings Mills Maryland 21117 postage prepaid with a payment of 10 00 to cover the costs of return postage and handling You must include a proof of purchase rec...

Отзывы: