NORMAL OPERATION

In normal operation, the alarm will blink the green LED off once approximately every
20 seconds.

SERVICE/TROUBLE CONDITION

Periodically, the alarm's measurement circuit is tested. If an error is detected, the
alarm will sound a double "beep" and the yellow LED will flash on twice approximately
every 40 seconds. This is an indication of circuit malfunction and that the alarm required
immediate servicing.

When AC power is lost, the green LED is off and flashes on approximately every 60
seconds.

MAINTENANCE

BATTERY REPLACEMENT (Model USI-7390 only)

The CO alarm is powered (backup) by a 9V battery. A fresh battery should last for one
year under normal operating conditions. This alarm has a low battery monitor circuit
which will cause the alarm to sound a short "beep" approximately every 40 seconds,
for a minimum of 7 days, when the battery gets low. Replace the battery when this
condition occurs, by using the QUICK DRAW

TM 

pull-out battery drawer for easy

replacement.

Slide the QUICK DRAW

TM 

pull-out battery drawer out. While observing polarity, push

the replacement battery into the battery drawer until it is held securely in place. Carefully
close and latch the QUICK DRAW

TM 

pull-out battery drawer.

USE ONLY THE FOLLOWING 9 VOLT BATTERIES FOR CO ALARM
REPLACEMENT

Alkaline type:

EVEREADY 522; DURACELL MN1604

Lithium type:

ULTRALIFE U9VL-J

NOTE: REGULAR TESTING IS RECOMMENDED.

USE ONLY THE BATTERIES SPECIFIED. USE OF DIFFERENT BATTERIES MAY
HAVE A DETRIMENTAL EFFECT ON THE CO ALARM. THE CONSTANT
EXPOSURES TO HIGH OR LOW TEMPERATURES OR HIGH HUMIDITY MAY
REDUCE BATTERY LIFE.

CLEANING YOUR ALARM

To clean your alarm, remove it from the mounting plate as outlined in the beginning of
this section.

You can clean the interior of your alarm by using your vacuum cleaner hose and
vacuuming through the openings around the perimeter of the alarm.

The outside can be wiped with a damp cloth. Do not use any household cleaning
agents, ammonia based cleaners, paints, varnishes or any other chemical on or near
your alarm. 

AFTER CLEANING, REINSTALL YOUR ALARM. TEST YOUR ALARM

BY USING THE TEST BUTTON.

Disconnect AC power before changing battery. Shock hazard exists if AC power
is miswired.

Содержание USI-7385/USI-7390

Страница 1: ...ent in other areas This product is intended for use in ordinary indoor locations of family living units It is not designed to measure compliance with Occupational Safety and Health Administration OSHA...

Страница 2: ...his equipment Make sure that motor vehicles are not and have not been operating in an attached garage or adjacent to the residence INSTALLING THE ALARM FOR RESIDENTIAL USE LOCATION One of the most imp...

Страница 3: ...lies or similar contaminants are used Excessive spillage or reverse venting of fuel burning appliances caused by outdoor ambient conditions such as Wind direction and or velocity including high gusts...

Страница 4: ...stible gas such as natural gas propane or butane heat smoke or flames NOTE This CO alarm is designed for use within a single residential living unit only In a multi family building the alarm may not p...

Страница 5: ...serious electrical shock injury or death TAMPER LOCKING PIN To make your alarm somewhat tamper resistant a locking pin has been provided Using this pin will deter children and others from removing the...

Страница 6: ...urn on AC power and press the TEST RESET button and check the LED s for proper operation see TESTING YOUR ALARM After test sequence the green LED lights to indicate AC power and blinks off approximate...

Страница 7: ...QUICK DRAWTM pull out battery drawer out While observing polarity push the replacement battery into the battery drawer until it is held securely in place Carefully close and latch the QUICK DRAWTM pul...

Страница 8: ...cover the costs of return postage and handling You must include a proof of purchase receipt along with the returned product USI DOES NOT WARRANTAND SPECIFICALLY DISCLAIMSANY WARRANTY WHETHEREXPRESSORI...

Отзывы: