Command Response
Description
s
###xyz
Returns the status of the SugarCUBE.
### - LED intensity (with leading 0’s if
necessary)
x
: + Indicates the LED is on.
- Indicates the LED is off.
y
: u – Indicates overlay buttons are unlocked.
l - Indicates overlay buttons are locked.
z
: Unit type:
1 - White LED
2 - Red LED
3 - Green LED
4 - Blue LED
5 - Quad White LED
6 - Lensed White LED
7 - Ultra
t
x[cr]
Indicates the LED case temperature in °C.
c
x[cr]
Returns a temperature reading every second in
°C.
This command is a toggle, so the first time a
“c” is received, the temperature starts
reporting. The second time a “c” is received,
the temperature stops reporting.
+
None
Turns the LED on.
-
None
Turns the LED off.
lock[cr]
None
Disables overlay buttons.
unlock[cr]
None
Enables overlay buttons. [default]
?
v##.##.##
Returns the firmware version
#
nnnnnnnnnn<cr
>
Returns 10 digit serial number of unit with
leading zeros.
All other
characters
The unit may be
rendered
unusable
Choosing other characters or character
combinations is not recommended as it may
cause the unit to cease functioning.