CLEANING & MAINTENANCE

WATER DRAIN PLUG

OPEN SCREWS

DRAINING AND CLEANING THE WATER TANK
•  Turn the power “off” and disconnect the air cooler from the power supply.
•  Move the unit to a location where it can be drained. Remove the cap from the 

water drain plug and allow the tank to empty (see parts description on page 9).

•  After you have drained the water tank, please connect the water drain plug to its 

original position.

•  Now refill the water tank up to Max level, wait for 5 min. and then drain the entire 

water once again. Use clean water for this procedure, so that maximum dust 
particles and remains are completely removed.

•  If your cooler has not been used for a long duration, we advise you to clean the 

water tank at least 2 times before it is used again.

CLEANING THE HONEYCOMB MEDIA
•  Turn off the unit, and unplug the power cord from wall outlet Rotate the unit 

facing the back panel, and locate the Rear Grill

•  Removal Screws (refer page 9., #12). Remove the screws with a screw driver.
•  Pull the rear grill panel upwards, until it is completely removed. Now, the 

honeycomb media can be seen. Clean the honeycomb media with fresh water.

•  Once the cleaning has been completed, assemble the unit as described above.
•  Plug into the power supply and turn unit on.

17

16

CLEANING & MAINTENANCE

IMPORTANT
•  The cooler is supplied with Honeycomb Cooling Media.
•  The cleaning frequency for the Honeycomb media depends on local air and 

water conditions. In areas where the mineral content of water is high, mineral 
deposits may build up on the Honeycomb Cooling Media and restrict air flow. 
Draining the water reservoir and refilling with fresh water at least once a week 
will help reduce mineral deposits. If mineral deposits remain on the Honeycomb 
media, the media should be removed and washed under fresh water. The media 
should be cleaned every two months or sooner, depending on your needs.

  Do not run the unit in COOL mode with stale water in the tank. Empty the tank 

and refill it with fresh water if the water has been standing in the tank for an 
extended period of time.

•  For best results, allow the Honeycomb Cooling Media to dry after each use by 

turning off the cool function 15 minutes before turning the unit off.

•  Draining the water reservoir and refilling with fresh water at least once a week 

will greatly reduce mineral deposits in the pads and help to extend the life of 
Honeycomb Cooling Media.

WARNING
•  Before cleaning the unit, switch it to the “off’’ position and remove the plug from 

the power socket.

•  To clean the outside, use a damp cloth to remove dirt and dust.
•  Never use corrosive elements or any chemicals to clean this product.
•  When the product is not in use, store the unit in a dry place out of direct sunlight.
•  Maximum water inlet pressure 0.5MPa

Содержание AIR KING

Страница 1: ...te www usha com Regd Office Surya Kiran Building 19 Kasturba Gandhi Marg New Delhi India Tel 91 11 23318114 Fax 91 11 23318118 Model CD504A 704A Power rating 190 Watts Rated voltage 230 Volt Rated fre...

Страница 2: ...structions carefully before setting up and operating the cooler and please keep this instruction manual for future reference This manual is designed to provide you with important information needed to...

Страница 3: ...of minimum 0 5 meters from the wall Not an Air Conditioner Important Please Read The evaporative air cooler is not an air conditioner as it does not use a compressor or refrigerant gas It should not b...

Страница 4: ...lative humidity level is 60 or less which allows a noticeable temperature decrease The temperature decrease will be greater in drier climates because higher evaporation occurs when the humidity is low...

Страница 5: ...ions DO NOT use in bathrooms Never locate the product where it may fall into a water container Store in a dry area when not in use This appliance is not intended for use by persons including children...

Страница 6: ...ly adjust the louvers to change vertical air flow 11 10 SMART SHIELD TECHNOLOGY POWERED BY N9 Water Tank Treated with Anti Bacteria Additive USHA Coolers now come with Smart Shield Technology powered...

Страница 7: ...ATION 13 12 FAN SPEED Press the FAN SPEED button repeatedly to change the speed between 1 2 3 The indicator light will show the selected speed 3 HIGH 2 MED 1 LOW There is an increase decrease button o...

Страница 8: ...er level mark 15 14 REMOTE CONTROL POWER ON OFF FAN Controls fan speed 3 2 1 off SPEED Increase fan speed Decrease fan speed COOL Controls cooling or fan operation SWING Controls the vertical swing mo...

Страница 9: ...IMPORTANT The cooler is supplied with Honeycomb Cooling Media The cleaning frequency for the Honeycomb media depends on local air and water conditions In areas where the mineral content of water is h...

Страница 10: ...ging the mechanical knob position of the control panel Motor Faulty Contact Service centre Not Cooling Unit is making noise Pump is not turned ON On control Panel Turn COOL FUNCTION TO ON Low or no wa...