background image

Blutronium™ Serial Bluetooth Adapter – Datasheet & Quick Reference

 

www.USconverters.com

 

  

www.usconverters.com 

Page 7 

 

silence after the command is entered. The time interval between each entered characters 

should be: 

 [500ms] “<” [500ms] “<” [500ms] “<” [1500ms] 

<<<= 

Inquire the setting status of the “<<<” command. 

(Default) 

Enable the “<<<” command 

 

Disable the “<<<” command 

>>> 

 

Change the remote adapter from “Data mode” to “Command/configuration mode”. A minimum 

of 500ms data silence must appear before the command is entered and a minimum of 2000ms 

data silence after the command is entered. The time interval between each entered characters 

should be: 

 [1 sec] “>” [1 sec] “>” [1 sec] “>” [2 sec] 

>>>= 

Inquire the setting status of the “>>>” command. 

(Default) 

Enable the “>>>” command 

 

Disable the “>>>” command 

ADDRESS= 

 

This command is used to display the Bluetooth address of the local adapter. 

 

Inquire the Bluetooth address of the local adapter. 

AT 

 

Checks the connection status between control terminal and the RS-232 adapter. Response: 
“OK” when the connection is ok. “ERROR” when the connection is unsuccessful.  

 

 

 

AUTO= 

 

This command is used to enable/disable the auto-connection feature. It is available only when 
the adapter is in Master mode and only when DIP=N. The system will not re-start after 
changing this parameter. 

 

Master and Slave will connect automatically.  

(Default) 

Master and Slave will need to be connected manually with the 'CONNECT' command.  

 

Inquire the current setting. 

BAUD= 

 

This command is used to specify the baud rate of the COM port. 
The command will need 200 ms delay. 

 

1200 

1200 bps 

 

2400 

2400 bps 

 

4800 

4800 bps 

*Default 

9600 

9600 bps *serial number 14090200 or lower has 19200 baud as default 

 

19200 

19200 bps 

 

38400 

38400 bps 

 

57600 

57600 bps 

 

115200 

115200 bps 

 

230400 

230400 bps 

 

460800 

460800 bps 

 

921600 

921600 bps 

 

Restore the default settings. (Baud rate = 9600 bps) 

 

Inquire the current baud rate. 

CONNECT= 

 

This command is used to establish a connection manually. It is available only when the adapter 
is in the Master role. 

 

DEVICE 

Connect the adapter to a specified Bluetooth device manually. 
It is available only when “DEVICE=xxxxxxxxxxxx” is executed. 

 

1~8 

Connect the adapter to a Bluetooth device in the neighborhood found through “SEARCH=?” 

 

xxxxxxxxx

Connect the remote adapter by typing the MAC address directly without searching. 

Содержание Blutronium B-TRON 5000

Страница 1: ...red over Bluetooth Internal rechargeable lithium battery Baud rates from 1200 to 921 600bps Basic configuration by DIP switches Communication range up to 300 feet Works with most mobile devices USB po...

Страница 2: ...ffer size 4Kb Operating distance Up to 330 feet 100 meters in open space LED lights Power Batt Status TX RX and Charging Bluetooth stack Serial Port Profile SPP PIN PIN code available for pairing Conn...

Страница 3: ...e Reverse Polarity SMA male inside threads center receptacle Antenna connector on adapter Reverse Polarity SMA female outside threads center pin Power options Mini USB cable 5VDC DB9 connector Pin 9 4...

Страница 4: ...ent the adapter is turned ON Position S W The adapter is using the parameters set by software by default the PROMPT AND ECHO parameters are enabled in this position Run Config Position Run The adapter...

Страница 5: ...r pin 9 Status LED off No pairing Status LED fast 0 1 sec blinking Pairing slave or master mode Status LED fast 0 3 sec blinking Discoverable and waiting for a connection slave mode Status LED slow 0...

Страница 6: ...tion The parameters can be configured over Bluetooth or through the adapter s serial port by using the Blutronium Configuration Utility which can be downloaded from https www usconverters com activate...

Страница 7: ...This command is used to enable disable the auto connection feature It is available only when the adapter is in Master mode and only when DIP N The system will not re start after changing this paramete...

Страница 8: ...to mode xxxxxxxxx xxx xxxxxxxxxxxx is a string of 12 hexadecimal digits R Restore the status in which the adapter can connect with any remote address Inquiry the designated address that can be paired...

Страница 9: ...racters in capital or lower case N Cancel authentication by PIN R Restore the default settings PIN 1234 Inquire the current PIN PROMPT This command is used to decide whether status messages are prompt...

Страница 10: ...ware version Inquire the version codes Some commands are unavailable under certain conditions If this command is set to These commands are unavailable ROLE S SEARCH CONNECT CONNECT P CONNECT xxxxxxxxx...

Страница 11: ...on reception which can be determined by turning the equipment off and on the user is encouraged to try correcting the interference by one or more of the following measures Reorient the receiving anten...

Отзывы: