Page 2
Problem
Possible Cause
Solution
Flow Meter is fluctuating
1. Pump is sucking air.
2. Restriction in the line.
3. Flow meter is not full of liquid
1.
Check and tighten all hose
connections.
1. Check filter to see if gasket is
missing or cracked.
2. Clean out filter and lines to
check for any debris.
3. The meter will fluctuate if
there is nothing pumping and
there is some liquid left in the
meter. Drain out liquid.
Flow meter won’t turn on
1. Improper power going to flow
meter.
2. Loose connection.
1. Check incoming power to
flow meter.
2. Check connections inside
the control panel and inside
the flow meter.
Flow Meter is reading too low or
too high.
1. Restriction in Flow Meter or
in line.
2. Air in treatment. This can
cause the flow meter to read
lower than calibrating it using
a measuring cup.
3. Seed flow has changed.
1. Flush the flow meter with
water or use compressed air
and blow air backwards
through the meter.
2. Check and tighten all hose
connections.
2. Check filter to see if gasket is
missing or cracked.
3. Recheck seed flow rate.
Flow meter will not zero
1. Improper wiring
2. Wrong parameter
programmed into flow meter
1. Check wiring schematic.
2. Check flow meter
parameters. Call local
dealer.