3
An “On / Off” screen appears. Press Right or Left keys to highlight and enable this
address (On) or disable this address (Off). Press the ENT key to select. The cap code
screen for this address appears.
To program a cap code, press the Right key to increment the value of the first digit, Left
key to decrement. Press the ENT key to shift to the next digit. If an invalid cap code is
entered, the display will return to the first digit. The valid cap code range is listed under
each cap code input [0000008-2097151]. After completing a valid input, the menu will
shift back to the Main Menu and allow other addresses, baud rate, and frequency to be
programmed. Press the Right key to increment through the selections.
After completing the cap code entries, the Main Menu will display the current Baud Rate
setting. If correct, press the Right key to shift to the Frequency selection. If the Baud
Rate setting needs to be changed, press the ENT key to shift to the Baud Rate screen.
512 bps / 1200 bps / 2400 bps selections will appear.
Use the Right or Left keys to highlight the desired setting, and press the ENT key to
select. The display returns to the Main Menu screen and shows the new Baud Rate
setting.
The last programming menu is the Frequency setting.