Hardware Installation
2-18
Hardware Installation
•
Use a high quality shielded cable for the Digital Audio. See the chart below.
Note: The cable shield should be grounded on the chassis end only; this pre-
vents ground loops from occurring.
•
Use shrink tubing around the end of the wires and cups on the 26-pin high-density male
connector when assembling. This process helps prevent any shorting between adjacent
wires.
•
Tie all grounds together inside the connector shell. Use an EMI Gasket for this application.
•
Provide proper strain relief for the cable ends; use tie-wraps to anchor the cables as they
are installed.
•
Avoid running Digital Audio cables across or adjacent to AC power sources where possible.
•
Do not bundle wires close to chassis backplane, this increases connector stresses.
Recommended Cable
Maximum Cable
Length
Physical
Characteristics
Shielding
Belden 9992 (or better)
100 M. / 300’
9 pair / 24 AWG /
Stranded
Individual Shields
and Drain wires
Belden 6387 (or better)
100 M. / 300’
9 pair / 24 AWG /
Stranded
Individual Shields
and Drain wires
Belden 1800A (or better)
100 M. / 300’
1 pair / 24 AWG /
Stranded
Shield with Drain
Wire
Содержание Utah-400
Страница 1: ...The Utah 400 Digital Routing Switcher 144x144 Systems System Setup and Operation ...
Страница 14: ...TOC 6 The Utah 400 ...
Страница 18: ...F 4 List of Figures ...
Страница 31: ...144x144 Router 1 13 System Configurations FIGURE 1 4 144x144 with Redundant Crosspoints ...
Страница 32: ...Introduction 1 14 Introduction ...
Страница 46: ...Hardware Installation 2 14 Hardware Installation FIGURE 2 10 Utah 400 1442 Video Unbalanced Audio Rear Panels ...
Страница 66: ...Configuration and Operation 3 10 Configuration and Operation ...
Страница 94: ...Utah 400 Components 4 28 Utah 400 Components ...
Страница 124: ...Troubleshooting 5 10 Troubleshooting ...
Страница 134: ...Specifications A 10 Utah 400 Series ...