background image

12 

 Cooking 

Before using the equipment for the first time, use a mild detergent to wipe down for 

cleaning. Do not use corrosive or abrasive detergents. 
●Pour liquid edible oil or solid shortening into hydro-cylinder, and do not fill over the oil 
level line

;

 

●If there is shortening, change to the lowest temperature to prevent burning and 
charring

;

 

●Once temperature reaches the preset temperature place fryer basket in place. 
●If the smell of oil changes during the process of frying due to too high temperature or 
too many impurities in the oil

Change or filter oil to resolve;  

 

Install the matched cooking fume exhauster according to the local regulations of the 
char broiler; 

 

Make sure to keep the air natural circulation in the kitchen. 

 

Note: Each burner nozzle has been installed before delivery, normal use without 
change but only switching gas. 

 

Cleaning and Maintenance 

    This product is made with high quality stainless steel material, and should be maintained 
carefully. Clean frequently to ensure better performance. Cleaning frequency depends on the 
use intensity. Climate factors must also be taken into consideration.

 

Daily maintenance can 

improve the life of the boiler.  

 

Instructions to clean appliance regularly with recommended cleaning agents, if 
necessary. 

 

Clean the inner part of the hydro-cylinder, fryer basket, grid and drain oil pipe

:

 

    1.  Pour  moderate  water  and  detergent  into  hydro-cylinder  (Do  not  fill  over  the  highest 
height of the oil level line) 
    2. After mix fully, turn on the main fire burner heating, turn off the main fire burner after 
heating about 5-10 minutes;  
    3. Soak the hydro-cylinder, fryer basket and drain oil pipe in the solution for a period of 
time; 
    4.  When  water  temperature  cools  down  to  suitable  body  temperature,  wipe  the  hydro-
cylinder inner wall and  combustion tube surface with cleaning cloth, Use  cleaning cloth on 
the  fryer  basket,  grid  and  drain  oil  pipe.  Do  not  use,  wire  brush  or  a  hard  object  to  wipe 
surface of the hydro-cylinder, wipe along the

 direction of metal original polishing lines; 

    5. Turn on oil drain valve to empty slopes.  
    6. Rinse hydro-cylinder with clean water

Содержание USFF-300

Страница 1: ...Type Fryer Operating Instructions Before you begin please read these instructions carefully to use this product correctly to make the product perform ideally and to avoid hazards Models USFF 300 USFF...

Страница 2: ...onvenient reference and operation This instruction manual is subject to any change without further notice and the manufacturer reserves the right of final interpretation This appliance is designed for...

Страница 3: ...ntroduction 4 Manufacturer s Authority and Responsibility 4 Parameter Specifications 5 7 Transport and Storage 8 Installation and Debugging 8 9 Safety Notices and Precautions 10 Operating Instructions...

Страница 4: ...series of gas fryers in our company production Which is quality designed reasonably structured conveniently operated durable and conveniently maintained Equipped with a high efficiency cast iron burne...

Страница 5: ...5 Parameter Specifications Outline Dimensions inch USFF 300 USFF 400...

Страница 6: ...6 USFF 500...

Страница 7: ...l of burners and control method Gas Species Intake tube pressure in W C Per BTU B T U h Total BTU B T U h Nozzle No USFF 300 3 pieces Integrated control Natural Gas 4 34 000 102 000 36 L P Gas 10 30 0...

Страница 8: ...nstallation Code CSA B149 2 as applicable The appliance shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1...

Страница 9: ...w it with a self tapping screw Specific installation steps and methods see Fig 2 Fig 3 for reference Keep a distance of at least 6 inches 152mm to equipment s sides and back and keep distance of at le...

Страница 10: ...ustion effect even cause severe accidents Turn off the equipment as not in use or no operator here Turn off the equipment while repairing maintaining or cleaning If the equipment has any problems of e...

Страница 11: ...he main burner After lighting the pilot light turn on the main valve by turning temperature control knob clockwise ignite the main burner by the pilot light turn temperature control knob to proper tem...

Страница 12: ...ained carefully Clean frequently to ensure better performance Cleaning frequency depends on the use intensity Climate factors must also be taken into consideration Daily maintenance can improve the li...

Страница 13: ...the manufacturer service agent or a similarly qualified person in order to avoid a hazard Warning Before cleaning all control valves must be turned off Strictly follow the lighting instructions to wo...

Страница 14: ...l Gas W C Use a pressure gauge which is equipped with liquid such as U type pressure gauge the minimum value is 0 1mbar or a digital pressure gauge to test Steps are as follows Reference picture to ri...

Страница 15: ...ils in place read number when temperature stabilizes 3 If the set temperature and measurement temperature difference at 10 degrees Fahrenheit Check temperature again 4 Delete number on the B make sure...

Страница 16: ...nd thermoelectric couple 1 2 inches the fire must be large enough to keep the thermocouple being red or cannot keep the safety valve open 1 Remove controller copper adjusting cap 2 Adjust controller k...

Страница 17: ...fire nozzle occlusion 2 Dredge nozzle 3 Gas control valves have problems 3 Change gas control valves 4 The pilot light and the main fire s distance is too far 4 Adjust the distance of them 5 Flame is...

Страница 18: ...le diameter 3 Not enough air to ignite 3 Increase damper opening degree 4 In the peak of using gas sources of gas float heavy 4 Turn down valves flow Turn it up after the peak Table 2 Cont The problem...

Страница 19: ...by other companies our company has the right not to provide warranty service Order replacement parts from authorized representatives and after sale service agency Provide the model no serial no and d...

Страница 20: ...SFF 300 400 500 3 21201001007 Door assembly 1 392 34 529 USFF 300 400 21201003007 532 34 529 USFF 500 4 301060016 Upper axillare assembly USFF 300 400 500 5 21101001032 Front panel 1 USFF 300 400 2110...

Страница 21: ...3005 536 240 158 USFF 500 12 21201001006 Internal upper smokestack assembly 1 278 268 98 USFF 300 21201002006 348 268 98 USFF 400 21201003006 418 268 98 USFF 500 13 21201001002 hydro cylinder assembly...

Страница 22: ...3 4 USFF 300 400 500 21 301030003 Safety valve 1 343811404A USFF 300 400 500 22 301050002 loose joint 1 3 4 USFF 300 400 500 23 301070016 Nozzle windpipe welding assembly 1 USFF 300 301070017 USFF 40...

Страница 23: ...500 Accessories List Table 4 Model USFF 300 USFF 400 USFF 500 Adjustable steel leg 4 pieces 4 pieces 4 pieces Frying basket 1 piece 1 piece 1 piece Flat screen 1 piece 1 piece 1 piece Oil drain pipe...

Страница 24: ...and low maintenance charge Keeping some components and necessary maintenance updated can prolong the length of the product Contact the dealer for assistance Follow the format in figure 8 and table 3 U...

Отзывы: