Adjusting the RO System Flow Rates
1.
Be sure the pre
-
treatment systems have been flushed and put in service. If anti
-
scalant is being used,
be sure to confirm the dose and mix of the solution with the sales rep before starting the system.
2.
If possible remove the prefilter and fill it with water. This will remove the majority of the air in the system.
3.
Make sure the water supply is turned on and that you have a minimum of 30 PSI pressure to the system.
The optimal pressure would be 60 PSI.
NOTE:
SYSTEM RUNNING PRESSURE CANNOT FALL BELOW 30 PSI.
4.
Open the concentrate valve completely by turning it counterclockwise. Close the concentrate recycle
valve (if applicable) completely by turning it clockwise.
5.
Turn RO system to the AUTO position.
6.
Let the system run for 5
-
10 minutes to flush the remaining air out of the filters and membranes.
NOTE:
The system may need to be shut off and turned back on several times to flush the air out
and for the system to continue to run. This may be increased if the sediment filter is not
filled with water first.
4.
Check the running inlet pressure. The pressure should be between 40
-
60 PSI (
30 PSI minimum
) dur-
ing operation to ensure the system will not shut down due to a low pressure fault.
5.
Adjust the system to the designed flow rates without exceeding 150 PSI on the pump/membrane pres-
sure gauge. This adjustment is system and site specific. The concentrate valve, the concentrate recy-
cle valve and the throttle valve on the pump will need to be balanced so the RO meets the designed flow
rates for each stream without exceeding 150 PSI on the System Pressure gauge.
RO Start
-
up
WARNING:
NEVER
EXCEED
THE
MAXIMUM
PRESSURE
RATING
OF
YOUR
SYSTEM.
Adjust
the
pump
throttle
valve
and
concentrate
valve
until
the
correct
flow
is
achieved.
For
example,
DEFENDER
-
4000
should
be
adjusted
until
it
produces
about
4000
GPD
or
2.78
GPM
of
permeate
(product
water)
at
77˚F.
The designed flow may
be
achieved
below
150
PSI but it is IMPORTANT not to
exceed 150 PSI on the System Pressure when adjusting.
System
Size
Targeted Permeate
Flow
Concentrate Flow
(No Recycle)
Concentrate Flow
(With Recycle)
Concentrate
Recycle Flow
Maximum System
Pressure
Defender
2000
1.39 GPM
3 GPM
0.5 GPM
2.5 GPM
150 PSI
Defender
4000
2.78 GPM
3 GPM
1 GPM
2 GPM
150 PSI
Defender
6000
4.17 GPM
3 GPM
1.5 GPM
1.5 GPM
150 PSI
Defender
8000
5.56 GPM
3 GPM
2 GPM
1 GPM
150 PSI
Defender
12,000
8.33 GPM
6 GPM
2.78 GPM
3.22 GPM
150 PSI
Содержание Defender 223-DFROM Series
Страница 16: ...16...
Страница 26: ...26 DEFENDER Flow Diagram...
Страница 27: ...27 DEFENDER Flow Diagram...
Страница 28: ...28 Typical System Layout Drawing...
Страница 29: ...29 Controller Programming Options...
Страница 30: ...30 Controller Programming Options...
Страница 31: ...31 Controller Programming Options...
Страница 32: ...32 DEFENDER Electrical Schematic...