Installation Instructions 

Reverse Osmosis/Deionization Water System 

Page 3 

INSTALLATION STEPS 

NOTE: All plumbing must be completed in accordance with 
state  and  local  plumbing  codes.  Some  municipalities  may 
require  the  installation  be  performed  by  a  licensed 
plumber. Check with the local authority prior to installation. 
 

A. 

Install  all  supplied  filters  and  membrane  in  the  filter 

module.  The filters should be installed as shown below; 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
The  filter  housing  on  the  bottom  of  the  unit  can  be  removed 
buy turning them counter-clockwise.  Once removed be sure 
the  O-ring  that  seals  each  housing  is  in  the  groove  on  the 
housing sump.  Unwrap the filter and install it in the housing.  
Be  sure  the  gaskets  are  in  place  on  the  carbon  filter  and  DI 
cartridge.    Install  the  sumps  by  turning  them  clockwise.    Be 
sure not to cross thread the housing.  Housings should “spin” 
in  to  place  and  thread  easily.    If  not,  they  may  be  cross 
threaded.    Once  the  housing  is  hand  tight,  tighten  it  an 
additional 1/2-3/4 turn with the supplied filter wrench.   

B. 

Install  the  membrane  in  the  membrane  housing  by 

removing  the  1/4”  tube  from  the  cap  side  of  the  membrane 
housing.  This can be done by pressing the collet down toward 
the fitting, then pulling the tube out of the fitting (see page 6).  

Once the cap is removed be sure that the O-rings are in place.  
Unwrap the membrane and install it in the housing.  Be sure 
the membrane is fully seated in the housing.  This can be done 
by  pushing  on  the  center  pipe  in  the  membrane  with  the 
thumb.  There are two O-rings on the membrane center pipe 
that must be seated in the  housing.  Once the membrane is 
fully  seated  in  the  housing  install  the  cap  on  the  membrane 
housing and tighten hand tight.  Now re-install the 1/4” tube in 
the fitting on the membrane cap by pushing the tubing in the 
fitting.  Be sure the tubing is pushed all the way in the fitting.   
 

C. 

Insert  the  supply  1/4”   tubing  in  the  “ IN”   port  on  the 

sediment filter housing on the filter module.  This tube should 
be supplied with soft water if possible.  It is recommended that 
there be a shutoff valve for this line to shut the water supply off 
during maintenance endeavors.   
 

D. 

Install the 1/4”  drain tube in the flow restrictor on the 

filter module and run this to a drain.  A proper air gap should 
be maintained where applicable.  
 

E. 

Install the 3/8”  product line in the “ OUT”  port on the DI 

cartridge  housing  on  the  filter  module.    This  line  should  be 
conveyed to a tank or other point of use.  This line must have a 
shutoff device such as a valve installed in the product line if the 
supplied automatic shutoff valve (ASO) is to be used to shut 
the system down.  If this line is left open there is no way to shut 
the system down other than a manual shutdown of the main 
feed water supply valve.   
 

F. 

The system can be mounted to a wall or to the inside of 

a  cabinet  if  desired.    Use  the  supplied  “key  holes”  in  the 
bracket to mount the filter module.   
 

MEMBRANE 

PRE SEDIMENT 

DI CARTRIDGE 

PRE CARBON 

Содержание 200-RODI4 series

Страница 1: ...nd Maintenance Manual US Water Systems 1209 Country Club Road Indianapolis IN 46234 1 800 608 8792 www uswatersystems com US Water 4 Stage RO DI System REVISION 1 0 5 12 2015 Owners Manual Models 200...

Страница 2: ...ve ASO PRE FILTER sediment filter removes larger particles such as sand silt rust and scale activated carbon filters re move chlorine in the feed water to protect the reverse osmosis membrane REVERSE...

Страница 3: ...ure the membrane is fully seated in the housing This can be done by pushing on the center pipe in the membrane with the thumb There are two O rings on the membrane center pipe that must be seated in t...

Страница 4: ...valve and allow the system to run until there is no air in the water stream 2 Close product water valve and re fill the system 3 Allow system to process water until the tank is full or the system is p...

Страница 5: ...feed water valve and leave the product line open 11 Allow the system to de pressurize 12 Remove housings and empty the water 13 Remove any protective wrap from pre filters and membrane and install the...

Страница 6: ...ditions of 77 F 25 C and 60 psi 4 bar discharging to atmosphere These factors should be considered when sizing RO systems for a particular application Every degree of temperature below 77 F will reduc...

Страница 7: ...site and or before use Disconnecting Push in Collet and remove tube To disconnect ensure the system is depressurized before removing the tube Push in collet squarely against face of fitting With the c...

Страница 8: ...Installation Instructions Reverse Osmosis Deionization Water System Page 8...

Страница 9: ...Installation Instructions Reverse Osmosis Deionization Water System Page 9...

Страница 10: ...Installation Instructions Reverse Osmosis Deionization Water System Page 10...

Страница 11: ...HE TERMS OF THIS EXPRESSED WARRANTY AND THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THOSE HEREIN US WATER SYSTEMS INC SHALL NOT BE LIABLE WHATSOEVER FOR ANY INCIDENTIAL AND OR CONSEQUENTIAL DAMAGES SO...

Отзывы: