Document Title:
MTP
®
Loopback Casing Installation
Document Number: AEN-1430, Rev. 1.0
7 of 17 THE USE OF SAFETY GLASSES FOR EYE PROTECTION IS RECOMMENDED
3.1b.2
Load the fibers in a disposable loose fiber ribbonizing tool as shown in
Figure 3.1b.2. Refer to US Conec Document AEN-1414, “Operating
Instructions for the US Conec Disposable Loose Fiber Ribbonizing Tool”
to select the appropriate ribbonizing tool. The 40mm marks made on the
fibers in Step 3.1b.1 indicate the starting point for ribbonization. Adjust
the fibers in the tool so that the marks are aligned. Follow the instructions
in AEN-1414 to ribbonize the fibers on one end of the ribbon.
Figure 3.1b.2
3.1b.3
Load the fibers on the other end of the ribbon in the ribbonizing tool in the
same order as the previous step. Ribbonize the fibers starting at the 40mm
mark.
3.1b.4
Mark the ribbon 12mm from the start of ribbonization at both ends of the
ribbon.
Figure 3.1b.4