18
CARTRIDGE FILTER MAINTENANCE
WARNING: Always disconnect the plug
from the wall outlet before removing the tank
cover.
NOTICE: This filter is made of high quality pa-
per designed to stop small particles of dust.
The filter can be used for wet or dry pick-up. A
dry filter is necessary to pick up dry material.
If you use your vac to pick up dust when the
filter is wet, the filter will clog quickly and be
very difficult to clean. The filter may become
saturated when picking up large quantities of
liquid causing misting to appear in the exhaust
air. At this time, you should dry or change
the filter to eliminate this occurrance. Please
handle the filter carefully when removing it for
cleaning or when installing it.
Check the filter for tears or small holes. Even a
small hole can cause dust to be exhausted. Do
not use a filter with holes or tears. Replace it
immediately.
INSTALLING & CLEANING
1. Slide cartridge filter down
over filter cage.
2. Place filter retainer on top
of cartridge filter.
3. Hold onto base of lid cage
with one hand and turn re-
tainer clockwise to tighten.
4. To remove filter for clean-
ing, again hold onto base of
lid cage with one hand and
turn retainer counter clock-
wise to loosen.
5. Slide cartridge filter off fil-
ter cage.
6. Clean dry filter by tapping it
on inside of waste can.
7. Clean wet filter by rinsing
from the inside.
8. When wet (to prevent mold and/or mildew
build-up), the cartridge filter should be re-
moved and allowed to air dry for a 24-hour
period before being re-installed back onto the
filter cage.
TROUBLESHOOTING
PARTS/ACCESSORIES MISSING
Packed in tank: Check in tank.
VACUUM CLEANER WILL NOT START
No power at receptacle: Check for power.
Defective switch: Replace switch.
Defective motor: Replace motor.
DUST DISCHARGING FROM EXHAUST
Filter not installed/not installed properly:
Properly install filter.
Filter damaged: Replace filter.
Filter clogged or dust is too fine: Use more ef-
ficient filter.
Filter not functional: Clean and replace filter.
LOSS OF SUCTION
Loose hose connection: Tighten hose connec-
tion.
Filter clogged: Clean or replace filter.
Full tank: Empty tank.
Hole in hose: Replace hose.
STATIC SHOCK
Dry environment: Add moisture to air (if prac-
tical, use a console or installed humidifier).
Relative humidity of air is low: This situation is
temporary and does not affect the use of the
vacuum cleaner.
TANK CAPACITY
ACCESSORIES DIAMETER
AIR FLOW
SUCTION
CURRENT
VOLTAGE-FREQUENCY
WEIGHT
18 gal (68 L)
2 1/2" (63,5 mm)
100 CFM (2,8 m³/min)
80" (2 m)
7,4 A
120 V ~ 60 Hz
13,1 kg (28,8 lb)
AS818
AS810
TANK CAPACITY
ACCESSORIES DIAMETER
AIR FLOW
SUCTION
CURRENT
VOLTAGE-FREQUENCY
WEIGHT
10 gal (38 L)
1 1/2" (38,1 mm)
100 CFM (2,8 m³/min)
80" (2 m)
7,4 A
120 V ~ 60 Hz
15 kg (33 lb)
1
2
3
4
5
6
7
TECHNICAL DATA
AS810 & AS818 manual.indd 18
28/05/15 15:34