urmet domus Sinthesi Steel 1060/74 Скачать руководство пользователя страница 5

9

DS1060-112B

EXTERNAL CAMERA CONNECTION

Instead of the camera present in the module, an 

external camera can be connected to terminal pins 

V3, V5.  

To enable the external camera, move the jumper as 

shown below. 

WIRING INSTRUCTIONS WITH CAT5 WIRE

Fit the CAT5 wire in a RJ45 plug with Urmet logo:

Insert the wire in the guide respecting the colour coding shown (Standard T568B).

8

1

Wire

No.

Wire colour

1

White-Orange

2

Orange

3

White-Green

4

Blue

Wire

No.

Wire colour

5

White-Blue

6

Green

7

White-Brown

8

Brown

Cut the wires which protrude from the guide by approximately 5 mm, insert the guide in the plug and 

crimp the plug with a speci

fi

 c tool.

Plug

8

1

~ 5 mm

8

1

  Make sure that the grey sheath remains inside the plug.
  This type of connection DOES NOT ensure double insulation.

TECHNICAL SPECIFICATIONS

POWER VOLTAGE AND CONSUMPTION ON TERMINALS V+ V-

Power voltage: ...............................................................................................................................

44 ÷ 57 Vdc

Current consumption during video call (*) @48 V: ................................................................................

200 mA

Current consumption in standby (*) @48 V: ..........................................................................................

140 mA

Working temperature range: ..................................................................................................

-10 °C ÷ +50 °C

(*) Current consumption of 30 external name holder tags is included.

Relay contact range C, NC, NO:

  Maximum switching voltage:  ................................................................................................................

30 V

  Maximum switching current:  ...............................................................................................................

3,5 A

  Maximum switching load:  .........................................................................................................

40 VA 25 W

Max. distance from hall button:  .............................................

25 m with cable cross-section area 0.5 mm

2

Max. distance from open door sensor:  .................................

50 m with cable cross-section area 1.5 mm

2

Max. distance from supplementary power supply:  .............

100 m with cable cross-section area 1.5 mm

2

Max. distance from capacitance lock:  ................................

100 m with cable cross-section area 1.5 mm

2

RESTORE DEFAULT SETTINGS

Close the hall button and at the same time press the second button on the IP video door unit (the bottom 

most one) for 20 seconds. After 20 seconds, the device will beep before restarting, then release both 

buttons: the previous con

fi

 guration of the IP video door unit will be lost.

TLC-EXT