background image

sec.2b 

−−−− 

5

K-STEEL CALL MODULE

BIBUS 2

nd

 Ed. VOP - Technical Manual

Ref. 

072/

4

K-STEEL CALLING MODULE WITH REPERT

ORY

ADjUSTMENTS 

vOLUME ADjUSTMENT 

Volumes  are  calibrated  by  default  so  not  to  require  adjustments  in 

most cases.

Use a screwdriver to adjust the trimmers if required.

DISPLAY CONTRAST REGULATION

The  display  contrast  is  set  at  the  factory  and  will  not  need  to  be 

adjusted in most installations.

Use a screwdriver to adjust the trimmers if required.

K-STEEL CALLING MODULE WITH REPERTORY Ref. 072/4

ADjUSTMENTS - ADDITIONAL ALPHABETIC KEYBOARD REF. 038/73

INSTALLATION

ADDITIONAL 

ALPHABETIC 

KEYBOARD 

Ref. 038/73

The  additional  alphabetic  keyboard  Ref.  1038/73  can  be  used  to 

entered letters for dialling call codes.

The device must be combined with a calling module Ref. 1072/14 to 

which it is connected by means of the specific connection wire. In any 

case, the device must be arranged UNDERNEATH (or by THE SIDE 

OF) the calling module.

INSTALLATION

Calling module with repertory Ref. 1072/14 can be used alone or in 

combination  with  a  camera  unit  and/or  alphabet  keyboard  add-on 

Ref. 1038/73.

Examples of modular constructions using 2 or 3 module holder frames 

with respective flush-mounting boxes are shown below.

The door unit module should be installed at a height of approximately 

1.55 ÷ 1.60 metres.

Important 

The module should not be illuminated from behind to make the calling 

module  display  easier  to  read.  Never  direct  the  module  towards 

strong sources of light (e.g. the sun, lampposts, light bulbs, flashes 

or glare). 

FLUSH-MOUNTED vERSION 

The flush-mounting box and respective frame must be used for flush-

mounted installation.

The  available  models,  dimensions  and  box  and  frame  installation 

procedures are shown in Technical product manual - door phone and 

video door phone systems - section “Modular Vandal-Proof Panel K-

Steel”.

1.   Refer the protections from the hole to be used to pass the wires 

only from the flush-mounting box.

X

G

D

A

J

H

E

B

I

F

C

h = 1,55 

÷

 1,60 m

X

7

4

1

0

8

5

2

9

6

3

Содержание K-STEEL 1072/14

Страница 1: ...NGS 3 OPERATION 3 Calls to users 3 Direct call to concierge switchboard 4 Door opener codes 4 Busy function 4 adjustments 5 Volume adjustment 5 Display contrast regulation 5 ADDITIONAL ALPHABETIC KEYB...

Страница 2: ...ischarge and hold current with programmable activation time from 1 to 30s Programmable door phone pick up time 10 20 30 40s Programmable minimum guaranteed conversation time 10 20 30 40s Maximum conve...

Страница 3: ...tion SE2 Electrical lock connection MP2 terminal board L1 Bus line 1st wire L2 Bus line 2nd wire GND Reference electrical ground PA Hall door opener button input SP Open door sensor contact input MV1...

Страница 4: ...g a call The following message indicates busy status The keyboard is disabled during this time Two cases can occur BUSY TIME BEFORE THE CALL USER GOES ON HOOK This is the maximum time for the user to...

Страница 5: ...ERNEATH or by THE SIDE OF the calling module INSTALLATION Calling module with repertory Ref 1072 14 can be used alone or in combination with a camera unit and or alphabet keyboard add on Ref 1038 73 E...

Страница 6: ...tect all parts which will be exposed to view from mortar plaster and cement Never use abrasive detergents to clean units 3 Fit the flush mounting box in line with the wall it must not project The wall...

Страница 7: ...d with module holder frame The available models and the dimensions of cases and frames are shown in Technical product manual door phone and video door phone systems section Modular Vandal proof panel...

Страница 8: ...1072 14 Ref 1755 30A Ref 1755 30A Ref 1755 30A Ref 1755 30A Ref 1038 73 Ref 1038 73 Ref 1155 62 Ref 1155 61 Ref 1072 14 Ref 1155 62 S N Ref 1072 14 Ref 1072 14 Ref 1038 73 Ref 1038 73 Ref 1155 61 S N...

Отзывы: