background image

sec.2b 

−−−− 

BIBUS 2

nd

 Ed. VOP - Technical Manual

SECTION 2B

(REv.G)

CALL MODULE

K-STEEL CALLING MODULE WITH REPERTORY Ref.072/4     2

PERFORMANCE ..............................................................................2

STRUCTURE ....................................................................................2

DESCRIPTION OF TERMINALS AND CONNECTORS .....................3

TECHNICAL SPECIFICATIONS ........................................................3

DEFAULT SETTINGS........................................................................3

OPERATION .....................................................................................3

  Calls to users ................................................................................3

  Direct call to concierge switchboard ............................................4

  Door opener codes .......................................................................4

  Busy function ................................................................................4

ADjUSTMENTS ...............................................................................5

  Volume adjustment .......................................................................5

  Display contrast regulation ...........................................................5

ADDITIONAL ALPHABETIC KEYBOARD Ref. 1038/73 ....................5

INSTALLATION .................................................................................5

  Flush-mounted version .................................................................5

  Wall-mounted version with case and hood ..................................7

ExAMPLES OF MODULAR CONSTRUCTIONS ...............................8

PROGRAMMING   

 

 

 See section A

Download from www.urmet.com Technical Manuals area.

SECTION CONTENTS

Содержание K-STEEL 1072/14

Страница 1: ...NGS 3 OPERATION 3 Calls to users 3 Direct call to concierge switchboard 4 Door opener codes 4 Busy function 4 adjustments 5 Volume adjustment 5 Display contrast regulation 5 ADDITIONAL ALPHABETIC KEYB...

Страница 2: ...ischarge and hold current with programmable activation time from 1 to 30s Programmable door phone pick up time 10 20 30 40s Programmable minimum guaranteed conversation time 10 20 30 40s Maximum conve...

Страница 3: ...tion SE2 Electrical lock connection MP2 terminal board L1 Bus line 1st wire L2 Bus line 2nd wire GND Reference electrical ground PA Hall door opener button input SP Open door sensor contact input MV1...

Страница 4: ...g a call The following message indicates busy status The keyboard is disabled during this time Two cases can occur BUSY TIME BEFORE THE CALL USER GOES ON HOOK This is the maximum time for the user to...

Страница 5: ...ERNEATH or by THE SIDE OF the calling module INSTALLATION Calling module with repertory Ref 1072 14 can be used alone or in combination with a camera unit and or alphabet keyboard add on Ref 1038 73 E...

Страница 6: ...tect all parts which will be exposed to view from mortar plaster and cement Never use abrasive detergents to clean units 3 Fit the flush mounting box in line with the wall it must not project The wall...

Страница 7: ...d with module holder frame The available models and the dimensions of cases and frames are shown in Technical product manual door phone and video door phone systems section Modular Vandal proof panel...

Страница 8: ...1072 14 Ref 1755 30A Ref 1755 30A Ref 1755 30A Ref 1755 30A Ref 1038 73 Ref 1038 73 Ref 1155 62 Ref 1155 61 Ref 1072 14 Ref 1155 62 S N Ref 1072 14 Ref 1072 14 Ref 1038 73 Ref 1038 73 Ref 1155 61 S N...