background image

4

DS1039-006

5

DS1039-006

ENGLISH

DESCRIPTION

Gateway 1039/50 is intended for use in Ipervoice video door phone systems only. The Gateway is used for 

interfacing between road side (Ethernet - PoE digital section) and the analogue column.

Functions are:

Feeding device via Ethernet (PoE).

Connection to Ethernet line for digital data, audio and video transmission.

Audio signal analogue/digital and digital/analogue conversion.

Video signal digital/analogue conversion.

Analogue column video signal calibration test activation.

Sch.1039/50

POWER ON

BUS OUT

A2

V- V+

VIDEO TEST

LAN

A

B

C

D

E

G

F

A   RJ45 type connector for connection to Ethernet (PoE) via CAT5 cable (LAN).

B

 

Auxiliary power terminal board (V-; V+).

C

 

Auxiliary audio input/output terminal board (A2).

D

 

RJ45 type connector for connecting column power supply unit via CAT5 cable (BUS OUT).

E

 

Analogue column video calibration test button.

F

 

Red LED

 

Blinking: video test mode on

 

Steady on: data line error in column.

G

 

Green LED indicating device powered.

FEATURES

External power:    

44 ÷ 57Vdc

Max. consumption:    

150mA

Temperature:   

-5°C ÷ 45°C

Dimensions:     

180 x 80 x 90mm (10 modules DIN)

Weight:               

approximately 450g

INSTALLATION

Refer to the instructions contained in the system manual for wiring, maximum distances and con

fi

 guration 

operations.

The housing may be used both in DIN bar mounting and wall mounting by means of screws and spacers; 

please take care of mounting it in dry and repaired environments.

Use Urmet 1039/101 RJ45 connectors.

Insert the wires in the guide respecting the colour coding shown (Standard T568B).

WIRING INSTRUCTIONS WITH 1039/90 WIRE

Fit the black wire 1039/90 in a RJ45 plug with URMET logo:

Remove the black insulating sheath by pulling the two sheath breaking threads to facilitate accommodation 

of the wire in the 

fl

 ush-mounting box.

Insert the wire in the guide respecting the colour coding shown (Standard T568B).

Black sheath

8

1

Grey sheath

Wire

No.

Wire colour

1

White-Orange

2

Orange

3

White-Green

4

Blue

Wire

No.

Wire colour

5

White-Blue

6

Green

7

White-Brown

8

Brown

Cut the wires which protrude from the guide by approximately 5mm, insert the guide in the plug and 

crimp the plug with a speci

fi

 c tool.

~ 5 mm

8

1

Plug

8

1

Make sure that the grey sheath remains inside the plug.

This type of connection DOES NOT ensure double insulation.

§

§