6.5. DEFAULT CONFIGURATION
Parameter
Function
Default
Parameter 1
Door unit type
Main
Parameter 2
Door unit ID
Address 0
Parameter 3
Door opener
Privacy
Parameter 4
Call button enabling
Both buttons enabled
Parameter 5
Call button association with switchboard call
Not active
The “Number of external cameras” parameter is set by default to 1. To change parameter
con
fi
guration, see para. 8 “ADVANCED CONFIGURATION (WITH WIFI CONNECTION)”.
7. HOW TO RESET DEFAULT SETTINGS
Press the PROGRAM button (8) brie
fl
y to go to con
fi
guration state. The LEDs (1) will blink during this step.
Then hold the BUTTON (5) pressed for longer than 10 seconds.
The door unit will generate two 2-second long beeps and all parameters will be reset before exiting
con
fi
guration state.
8. ADVANCED CONFIGURATION (WITH WiFi CONFIGURATION)
Prepare the device as WiFi access point for advanced con
fi
guration of the audio door unit Ref. 1083/39.
To start this type of con
fi
guration, follow the instructions in the booklet which can be downloaded from the
Urmet website by scanning the QR Code shown below with the camera of your smartphone or tablet.
Voice alerts are possible if the audio door unit module ref. 1083/39 is connected to an ILA module ref.
1168/48.
http://qrcode.urmet.com/default.aspx? prodUrmet=144286&lingua=en
9. SPEAKER
VOLUME
ADJUSTMENT
Volumes are calibrated by default so not to require adjustments in most cases.
Use a screwdriver to adjust the speaker volume (10), if required.
10. DDA (DISABILITY DISCRIMINATION ACT) LED ACTUATION
- SYSTEM STATUS INDICATION
The system state is shown by the following indications which appear on the door unit front:
a) call in progress: LED
on green and voice message “CALL IN PROGRESS”
b) line engaged: LED
on red and voice message “THE LINE IS BUSY”
c) off-hook waiting time expired: voice message “THE USER IS NOT ANSWERING”;
d) conversion in progress: LED
on orange;
e) door open: LED green and “THE DOOR IS OPEN” voice message.
The voice messages are possible if the audio door unit Ref. 1083/39 is connected to the ILA
module Ref. 1168/48.