6
DS1760-021
JUMPER (JP3)
The following Jumper allows to adjust the line termination (Z) in case of in-out video door phone connection.
The line termination must be inserted into the last video door phone.
JP3
Termination inserted (default)
Termination not inserted
For position of jumpers
JP1
and
JP2
and dip-switch
SW1 no.1
refer to the next chapter of the following
handbook.
4. VIDEO DOOR PHONE PERFORMANCE ACCORDING TO
CONFIGURATION METHOD
;OL]PKLVKVVYWOVULJHUILJVUÄN\YH[LK^P[OKPɈLYLU[TL[OVKZ+LWLUKPUNVU[OLZLSLJ[LKTL[OVK
limitation will be present on the following performance.
Installation type (*)
Performance
Low rise block (Default)
(Power supply from
system BUS with WiFi
always active)
High rise block
(Power supply from
system BUS with
WiFi active after call
forwarding)
Local power
(Power supply from
local power supply unit
Ref. 1760/110)
Jumpers and DIP-
switches
JP1
JP2
SW1 n.1
=
ON
JP1
JP2
SW1 n.1
=
ON
JP1
JP2
SW1 n.1
=
ON
Delay time on
reception of call
forwarding to CallMe
app
No delay
10 seconds
No delay
CallMe app auto-on
Available
Not available
Available
Panic alarm signalling
to CallMe App
Available
Not available
Available
Содержание 1760/18