![urmet domus 1717/32 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/urmet-domus/1717-32/1717-32_installation-handbook_1062496005.webp)
5
DS1717-019
1
2
DISTaNceS, SecTIONS, caBLeS aND Tech SPecS
Type of connection
Max distance
Min - max cross
.section
Call to floor level
30.m
0,5.-.1.mm
Panic.Alarm
30.m
0,5.-.1.mm
Call.repeating.
30.m
0,5.-.1.mm
External.4.Vdc
5.m
0,5.-.1.mm
LAN
100.m
CAT5e.(*)
(*). To.ensure.longest-range.monitor.operation,.the.cable.must.be.a.class.5e.device.and.the.twisted.pairs’.
cross.section.must.be.AWG4.
. The.maximum.resistance.of.the.individual.wires.must.not.exceed.10ohm/100m.
. The.cable.must.be.up.to.the.following.standards:
. -.EIA/TIA.568-B..or.EIA/TIA.568-C.
. -.EN5088.3-1
. -.IEC.61156-5
. The.connection.between.the.monitor.and.POE.switch.must.be.ensured.by.a.single.cable.without.any.
extra.patch.cords.
POE.input.voltage:...........................................................................................................................
48-54
.
v
.
External.power.supply.voltage:.............................................................................................................
24
.
v
.
Max.consumption:.....................................................................................................................................
12 W
Display:...................................................................................................................................................
7” TFT
Touchscreen:...................................................................................................................................
capacitive
Resolution:.................................................................................................................................
1024 x 600 px
Brightness:.......................................................................................................................................
350 cd/m
2
Viewing.Angle.(H/V):........................................................................................................................
160° / 160°
Operating.Temperature:...................................................................................................................
-5 to 45°c
IPerHOME.CU.Consumption:.................................................................................................................
0.5 cu
Max.number.of.monitors.on.the.POE.ports.of.switch.1039/44:......................................................................
2
This product is intended to be powered by either any external power supply units, through
the connector M1 on the board CS1717-014 (18W, 24Vdc) or PoE, through the connector
CN505 whose power supply conforms to the limited power source (lPS) requirements and
is protected against short circuits and power surges in accordance with the EN 60950-
1:2006+a11+a1+a12+a2 requirements.
If.a.local.power.supply.is.used,.do.not.connect.the.LAN.input.to.the.switch.POE.outputs.