STEP 1:
Wheel Fitting
If fitting wheel assembly please refer to page 10
first and fit before positioning the post brackets.
1-1
Place the 3 piece post bracket on each
position of the cylinder base as shown.
1-2
Screw in the 3 pieces of M8 x 15mm bolts
on the bracket cylinder assembly.
1-3
Tighten each of the bolts.
STEP 2 :
2-1 Put the post on top of the 3 piece
post bracket assembly as shown.
2-2 Screw in the 6 pieces of M6 x 35mm
bolts and M6 nuts through each post hole.
2-3 Tighten each bolt.
STEP 3 :
3-1 Put the cylinder housing through the
post as shown.
6
PRECAUTIONS
Periodically check the whole gas system for leaks or
immediately if the smell of gas is detected.
Extinguish all open flames.
Never leak test while smoking.
If you cannot stop a leak, turn off the gas supply and
call your gas supplier.
The heater must be checked with a full cylinder.
Do not use the heater until all connections have passed
a leak test.
Only use parts recommended. Substitute parts can void
the warranty.
Gas connections on the appliance are leak tested at the factory prior
to shipment. A complete gas tightness check must be carried out at
the installation site.
•
Make a soapy solution of one part liquid detergent and one part
water. The soapy solution can be applied with a spray bottle,
brush or rag. Soap bubbles will appear where a leak is present.
•
Make sure the safety control value is in the OFF position.
•
Turn the gas supply ON.
•
If a leak is present, turn off the gas supply. Tighten any leaking
fittings, then turn on gas supply and re-check.
11
STEP-BY-STEP PROCEDURE
CAUTION & LEAKAGE TEST
PROCEDURE FOR A LEAKAGE TEST