background image

 
 
 
 

 

STEP 1: 

 
Wheel Fitting 

If fitting wheel assembly please refer to page 10  
first and fit before positioning the post brackets. 

 

1-1

 

Place the 3 piece post bracket on each 
position of the cylinder base as shown. 

1-2

 

Screw in the 3 pieces of M8 x 15mm bolts 
on the bracket cylinder assembly. 

1-3

 

Tighten each of the bolts. 

 
 

STEP 2 : 

 
2-1 Put the post on top of the 3 piece  
 

 post bracket assembly as shown. 

2-2 Screw in the 6 pieces of M6 x 35mm 
 

 bolts and M6 nuts through each post hole. 

2-3 Tighten each bolt.  
 
 
 
 
 
 

STEP 3 : 
 

3-1 Put the cylinder housing through the 
 

 post as shown. 

 
 

 

 
 
 
 
PRECAUTIONS 

  Periodically check the whole gas system for leaks or 

immediately if the smell of gas is detected. 

  Extinguish all open flames. 

  Never leak test while smoking. 

  If you cannot stop a leak, turn off the gas supply and  

call your gas supplier. 

  The heater must be checked with a full cylinder. 

  Do not use the heater until all connections have passed          

a leak test. 

  Only use parts recommended.  Substitute parts can void      

the warranty. 

 

 
 
 
 
 
 

Gas connections on the appliance are leak tested at the factory prior 
to shipment.  A complete gas tightness check must be carried out at 
the installation site. 
 

  Make a soapy solution of one part liquid detergent and one part 

water.  The soapy solution can be applied with a spray bottle, 
brush or rag.  Soap bubbles will appear where a leak is present. 

  Make sure the safety control value is in the OFF position. 

  Turn the gas supply ON. 

  If a leak is present, turn off the gas supply.  Tighten any leaking 

fittings, then turn on gas supply and re-check. 

 
 
 
 

11 

 

 

STEP-BY-STEP PROCEDURE

 

 

 

CAUTION & LEAKAGE TEST

 

 

 

PROCEDURE FOR A LEAKAGE TEST

 

 

Содержание BFX770

Страница 1: ... Urban Industry Limited All rights reserved www patioheaters4u com Printed in the UK Model No BFX770 Terrace Patio Heater Operating Instructions Safety Information 2 Assembly Parts 4 Setting Up 6 Heater Stand Location 9 Leakage Testing 11 Operation Storage 12 Before Requesting Help 13 Technical Data Specifications 14 Guarantee 15 Certified Please retain this manual for reference ...

Страница 2: ... lightening misuse neglect including poor maintenance incorrect adjustment or repair transit damage wear and tear use in improper manner or inconsistent with the technical safety standards in force 4 If at any time the appliance has been dismantled or repaired by an unqualified service person the guarantee shall become void 5 The purchaser s sole and exclusive remedy under this guarantee against U...

Страница 3: ...and maintenance is required Prior to each use check the patio heater for any wear to the hose regulator pilot and burner Do not transport heater while it s operating All leak tests should be done with a soapy solution NEVER USE AN OPEN FLAME TO CHECK FOR LEAKS Check the heater immediately if any of the following exists o The heater does not reach temperature o The burner makes a popping noise duri...

Страница 4: ...ll LPG cylinder Opening blocked Clean pipes Air in supply system Purge air from lines Loose connection Check all fittings Worn tilt switch Replace tilt switch Pilot will not Thermocouple worn Replace thermocouple stay on Loose connections Tighten connections Debris around pilot Clean dirty area Gas leak in line Check connections Lack of fuel pressure Low fuel in cylinder Burner will Thermocouple w...

Страница 5: ...e complete shut off period is necessary before re lighting the heater TO TURN OFF 1 Turn gas control knob clockwise to the stop position 2 Depress gas control knob and turn clockwise to shut off 3 Turn the gas cylinder off completely 12 Construction and Characteristics Steel housing pole and base Stainless steel burner with safety tilt shut off Stainless steel flame screen Variable pilot control p...

Страница 6: ...r leak test while smoking If you cannot stop a leak turn off the gas supply and call your gas supplier The heater must be checked with a full cylinder Do not use the heater until all connections have passed a leak test Only use parts recommended Substitute parts can void the warranty Gas connections on the appliance are leak tested at the factory prior to shipment A complete gas tightness check mu...

Страница 7: ... 4 3 Thread the hose down the post assembly 4 4 Fix the burner base vertically with the post ensuring the instruction label is below the ignitor and facing same direction STEP 5 5 1 Install 4 pieces of M6 x 10mm bolts and tighten each one 5 2 Locate hose at base of pole and thread on a jubilee clip 5 3 Fit the regulator supplied to hose and attach jubilee clip and tighten as shown STEP 6 6 1 Put 3...

Страница 8: ...or use only Always ensure adequate fresh air ventilation Always maintain proper clearance to combustible materials i e top 50cm 18 inches and sides 60cm 24 inches minimum see figure 1 Heater must be placed on firm level ground The heater must conform to local codes and storage handling of LPG Never operate heater in an explosive atmosphere where petrol or other flammable liquids or vapours are sto...

Отзывы: