Urban choice UC LOGIC 83AW Скачать руководство пользователя страница 3

GENERAL

Front loading resistance sensing tumble dryer with gas
heating.Reverse actiondrum tumble.Electroniccontrol.
2-temperature exhaust thermostat control.Induced air flow
enters dryer through front grille, some passes through the
gas burner into the rear ducting and some into the cooling
passages, this mixed air enters the drum through the rear
perforations,  passes  through  the  clothes,  lint  filter,  and 
the fan and is discharged through the vent at the rear.

CONNECTIONS
Gas pressure:Rp 1/2 (1/2”B.S.P.parallel internal thread).
Nominally 20mbar
Electric: 230V.50 Hz, earthed supply, 13A fuse.
(wall  socket  must  have  efficient  earth  connection  and 
correct polarity)

DIMENSIONS
Height 85 cms.(33 1/2”)
Width  59.6 cms.(23 5/8”)
Depth 57 cms.(22 1/2”)
Depth when rear vent hose assembled 60cms.(23 5/8”)

WEIGHT
With packing 37 kg
Without packing 36 kg

SUPPORT
Machine rests on 2 rear positioned rollers and 2 non
adjustable feet.

AIR-FLOW
Approximately 120 cubic metres per hour with capacity
clothes load.

IDENTITY
Manufacture date, and serial number are displayed on a
plate revealed when machine door is open.
The  first  4  numerals  identify  year  and  week  of 
manufacture.
The  last  6  numerals  identify the  machine.ALL
INFORMATION FROM THIS PLATE SHOULD BE
QUOTED IN ANY SERVICE COMMUNICATION.

COMPONENTS

DRIVE MOTOR
Permanent split capacitor (8µF)4 pole—Approx. 1/8 HP
Overload protection approx.130°C

BURNER
Pressed steel with slotted flame perforations.
Heat input:3.0kW (10235 Btu/hr).Injector 1.32 mm dia.
 

3

CONTROL

Type:Pactrol full sequence flame control, P16AGTD(CE)
414601. Ignition electrode gap to burner 3 to 4mm Flame
failure electrode (4213 078 52641).Height from heater
base to centre of electrode 27.0±0.5mm.

INLET THERMOSTAT
(Brown wires identification)
Bi-metal contacts normally closed.
Contacts open if airflow restricted.
Contacts open 130°C ±3°C
Contacts reset 100°C ±5°C

INLET TEMPERATURE LIMITER
(White wires identification)
Bi-metal contacts normally closed.
Contacts open if INLETTHERMOSTATfails.
Contacts open 143°C ±3°C
Contacts reset 100°C ±5°C

EXHAUST THERMOSTATS
Bi-metal contacts normally closed.
Normal Fabrics:Contacts open 60°C ±3°C
60°C (green spot Contacts reset 49°C ±4°C
identification)
Delicate Fabrics:Contacts open 50°C ±3°C
50°C (red spot Contacts reset 35°C ±3°C
identification)

DRUM
Volume 105 litres
Speed approx.50/59 r.p.m.
Capacity 7 kg dry cotton
Rotation clockwise 5 mins., anticlockwise 10 secs

TRANSMISSION
Poly-vee belt driven by vee-grooved motor pulley to outer
circumference of drum.

ELECTRONIC CONTROL
8  selectable  programmes  giving  choice  of  dryness  level 
and timed programmes.When drying is complete,
intermittent tumbling (anticrease) follows until the
machine is unloaded.

HEATER SWITCH
Single pole, ON/OFF, PUSH-PUSH
START SWITCH-momentary push switch.

R.F.I.FILTER
0.1µF +2x2x5mH +2M2

ACCESSORIES
VENT HOSE ASSEMBLY0312 001 01001
WALL/WINDOW VENT KIT0312 005 01001
STACKING KIT0312 003 01001
RESTRAINING KIT0312 006 01001

TECHNICAL DATA  

Содержание UC LOGIC 83AW

Страница 1: ...nstallation and Use Regulations 1998 Guidance may be obtained from the relevant parts of B S 7624 B S 5440 parts 1 and 2 B S 6891 current editions I E E Wiring Regulations and relevant Building Regula...

Страница 2: ...TIVE LVD 2006 95 EC EN60 335 1 EN60 335 2 11 GAS APPLIANCE DIRECTIVE GAS 90 396 EEC BS 5258 PART 17 1992 EN 1458 1 2000 ELECTROMAGNETIC COMPATIBILITY DIRECTIVE 2004 108 EC EN55014 EN 61000 3 2 EN 6100...

Страница 3: ...0 C BURNER Pressed steel with slotted flame perforations Heat input 3 0kW 10235 Btu hr Injector 1 32 mm dia 3 CONTROL Type Pactrol full sequence flame control P16AGTD CE 414601 Ignition electrode gap...

Страница 4: ...urniture and similar surfaces 4 VENTING The dryer must be fitted with an exhaust vent hose and the end either hung out of a window or fitted to a wall window vent connection Note Do not obstruct or ad...

Страница 5: ...e carried out by a competent person i e registered Engineer 9 STACKING Instructions for stacking if required are supplied with the stacking kit PROGRAMME The electronic control measures dryness by the...

Страница 6: ...be removed from the Motor Disconnect the Motor leads Withdraw the black headed pin 537 Exert an anti clockwise force to disconnect the bayonet fitting between the Fan Access Cover 447 and the back of...

Страница 7: ...Bearing Assy 270 to the Back Panel 24 Withdraw the 8 screws securing the Back Panel 24 to the Cabinet 196 Disengage the T piece Grommet from the slot in the Back Panel and lift off The Rear Seal 14 ca...

Страница 8: ...nnections tight does motor start Check br w wiring from input terminal to door switch Check connections clean and tight does motor start Refer to chart 2 Refer to chart 3 Refer to chart 4 START No No...

Страница 9: ...ire with boot Caution the other red wire is live Is voltage between heat selector switch and TB N 230V Exchange both exhaust thermostats 50 C and 60 C and inlet thermostat 130 C brown wires Does contr...

Страница 10: ...r light Exchange control unit Does gas light Check continuity of wiring between 4 Way housing and relevant solenoid also neutral wiring Check plug clean and tight Does gas light Fault in gas system re...

Страница 11: ...ad suitable Is filter clean Is vent hose or terminal unobstructed Is vent terminal unaffected by wind conditions that may cause back pressure Start No No No No Check gas pressure with all other applia...

Страница 12: ...12 ECO 83A...

Страница 13: ...403 394 369 196 386 248 370 376 199 11 10 URBAN CHOICE ECO 83A_ EXPLODED VIEW 1 353 352 211 552 377 235 372 213 201 203 232 218 217 219 13 249 556 556 366 365 364 363a 363 203a 359 367 362...

Страница 14: ...URBAN CHOICE ECO 83A_ 14 15 16 17 393 375 230 38 389 375 18 375 20 23 21 22 412 375 19 403 396 24 25 26 27 25 14 13 143 398 28 141 408 409 410 411 144 Exploded View 2...

Страница 15: ...248 440 442 441 445 446 447 448 356 250 229 406 13 32 29 30 31 456 458 459 445 454 455 URBAN CHOICE ECO 83A_ EXPLODED VIEW 3 15...

Страница 16: ...URBAN CHOICE ECO 83A 142 112 101 101a 427 125 16 Exploded View 4 466 477 444 467 465 463 468 464 438 439 266 270 432...

Страница 17: ...41 33 482 411 45 31 406 13 32 URBAN CHOICE ECO 83A 375 39 17 Exploded View 5...

Страница 18: ...ture Limiter 143 Deg C 4213 092 24151 2 39 Ignition Electrode 4213 092 08491 5 41 M4 x 10 Pan Screw 2522 180 40002 5 45 Solenoid Coil SCEM 4213 092 08501 5 101 Motor and Capacitor Assembly 4213 092 25...

Страница 19: ...40003 2 4 403 Roller Assembly 4213 092 35651 1 2 406 M5 Toothed Lockwasher 2513 611 01008 3 407 Hex Nut DC St Zn M5 2522 401 55012 1 2 408 Cable Clamp 2 4213 077 47303 2 409 Washer M5 Form A 2522 604...

Страница 20: ...ockwasher 2522 616 15007 5 537 W Button access cover 4213 078 26311 3 552 Knob Extension 4213 077 59953 1 555 Rear Panels Seal Kit 4213 092 28001 2 556 HT Lead 4213 176 00771 1 Bearing Pads Brush Seal...

Отзывы: