background image

8.

Installing the Light Kit 

and Glass Shade

CAUTION - To reduce the risk of electrical 

shock, disconnect the electrical supply circuit 

to the fan before installing the light kit.

Blue

White

Molded

Adaptor Plugs

Black

White

Mounting

Screw (3)

Light Kit

Assembly

LED

Module

Glass

Light Kit

Assembly

Raised

Dimples

Flat Area

Figure 14

Figure 15

Mounting

Screw (3)

Light Kit

Assembly

Light Kit

Adapter

Figure 13

PERIODICALLY CHECK THE SHADE IS SEATED 

FULLY CLOCKWISE IN THE LIGHT KIT PAN 

ASSEMBLY

1.  Loosen but do not remove two of three 

mounting screws from the fan motor 

assembly; Remove one mounting screw.

(Figure 13)

2.  Push the light kit pan up to the fan motor 

assembly so that the two loosened screw 

heads fit into the keyhole slots. Turn the 

light kit pan clockwise, tighten the screws. 

Re-install the screw that was removed in 

step 1 and tighten firmly.(Figure 13)

3.  Remove one screw from the light kit pan 

and loosen, but do not remove, the other 

two screws. Connect the wires from the 

light kit assembly to the wires from the fan 

motor assembly by connecting the molded 

adaptor plugs together. Carefully tuck 

all wires and splices into the switch cap. 

(Figure 14)

4.  Push the light kit assembly up so that 

the two loosened screw heads fit into the 

keyhole slots. Turn the light kit assembly 

clockwise, tighten the screws. Reinstall 

the screw that was removed in step 3 and 

tighten firmly. (Figure 15)

5.  Place the glass shade into the light kit 

pan, aligning the three flat areas on the 

top of the glass shade with the three raised 

dimples in the light kit pan. Turn the glass 

shade clockwise until it stops. (Figure 15)

THE GLASS IS FRAGILE, USE CARE WHEN 

INSTALLING THE LIGHT KIT AND THE GLASS 

SHADE.

Содержание UHP9220

Страница 1: ...UHP9220 UHP9221 UHP9222 ...

Страница 2: ...Safety Rules Unpacking Your Fan Installing Your Fan Making the Electrical Connections Operating Your Fan Care of Your Fan Troubleshooting Specifications Table of Contents 1 2 3 6 9 10 10 11 ...

Страница 3: ...ctrical connections spliced conductors should be turned upward and pushed carefully up into electrical box The wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the electrical box and ungrounded conductor on the other side of the electrical box 11 Electrical diagrams are for reference only Light kits that are not packed with the fan must ...

Страница 4: ...embly 6 Blades 3 7 Light Kit Pan 8 Light Kit Fitter Assembly 9 Glass Shade 10 Wall Control 1 Mounting Bracket inside canopy 2 4 5 Ball Downrod Assembly hanger pin and locking pin pre attached 3 Canopy with Canopy Ring attached 4 Decorative Motor Collar Cover 2 Unpacking Your Fan Unpack your fan and check the contents You should have the following items a b ...

Страница 5: ...oxes Figures 1 2 and 3 are examples of different ways to mount the electrical box Note You may need a longer downrod to maintain proper blade clearance when installing on a steep sloped ceiling The maximum allowable angle is 30 To hang your fan where there is an existing fixture but no ceiling joist you may need an installation hanger bar as shown in Figure 4 TO REDUCE THE RISK OF FIRE ELECTRIC SH...

Страница 6: ...y Figure 7 Remove Loosen but Do Not Remove Turn Canopy Ring to Remove Figure 5 Figure 6 5 Loosen but do not remove the set screws on the collar on the top of the motor housing 6 Align the holes at the bottom of the downrod with the holes in the collar on top of the motor housing Figure 7 Carefully insert the hanger pin through the holes in the collar and downrod Be careful not to jam the hanger pi...

Страница 7: ...d with the electrical box Note that the flat side of the mounting plate is toward the electrical box Figure 8 3 Tighten the two screws on the electrical box securely 4 Carefully lift the fan assembly up to the ceiling mounting plate Make sure the tab on the mounting plate is properly seated in the groove in the hanger ball Figure 9 Figure 8 Washers 120VWires ULListed Electrical Box Ceiling Mountin...

Страница 8: ...cuit breaker panel remove the existing wall plate and switch 2 Proceed to connect the wires as follows make sure the fan and light slide switches of the wall control are set in OFF position Connect the solid black wire from the wall control to the black wire from the fan Connect the red or blue wire from the wall control to the black wire from the fan Connect the black with white stripes wire from...

Страница 9: ... Run the fan for 10 minutes Finishing the Fan Installation STANDARD CEILING MOUNTING 1 Align the locking slots of the ceiling canopy with the two screws in the mounting plate Push up to engage the slots and turn clockwise to lock in place Immediately tighten the two mounting screws firmly 2 Install the remaining two mounting screws into the holes in the canopy and tighten firmly 3 Install the deco...

Страница 10: ...ght kit pan clockwise tighten the screws Re install the screw that was removed in step 1 and tighten firmly Figure 13 3 Remove one screw from the light kit pan and loosen but do not remove the other two screws Connect the wires from the light kit assembly to the wires from the fan motor assembly by connecting the molded adaptor plugs together Carefully tuck all wires and splices into the switch ca...

Страница 11: ...located at the top of the motor housing refer to figure 7 on page 4 to opposite position and turn fan on again The fan blades will turn in the opposite direction and reverse airflow Figure 16 Figure 17 Warm weather Forward A downward air flow creates a cooling effect as shown in Figure 16 This allows you to set your air conditioner on a higher setting without affecting your comfort Cool weather Re...

Страница 12: ...f shoe polish 4 There is no need to oil your fan The motor has permanently lubricated sealed ball bearings MAKE SURE THE POWER IS OFF AT THE ELECTRICAL PANEL BOX BEFORE YOU ATTEMPT TO MAKE ANY REPAIRS REFER TO THE SECTION MAKING ELECTRICAL CONNECTIONS Fan will not start Fan sounds noisy 1 Check main and branch circuit fuses or breakers 2 Check line wire connections to the fan and switch wire conne...

Страница 13: ... FAN SIZE SPEED VOLTS FAN POWER CONSUMPTION WITHOUT LIGHTS WATTS AIRFLOW CFM AIRFLOW EFFICIENCY HIGHER IS BETTER CFM WATT NET WEIGHT GROSS WEIGHT CUBE FEET 52 Low 120 9 1999 222 14 77 Lbs 16 54 Lbs 1 43 High 42 4306 103 ...

Отзывы: