Annual Product Calibration

This product is a high-precision measurement device with sensitive, please use with 
care. To ensure the accuracy of measurements, it is recommended to have the unit 
calibrated once a year. Please contact your agent or our customerservice department 
for calibration service.

Product Notes and Precautions

1. 

2.

Precautions / Warnings

Please read the following precautions to avoid fire, excessive heat, chemical leakage 
and explosion.



 

 

 

 

   

  
 

 

  

The MK550T Spectroradiometer contains sensitive components. Please unpack with 
care, as any trauma to the unit may damage the equipment. Contact your agent if the 
unit appears not to be operating normally. Do not attempt any repairs – all repairs 
must be performed by qualified service agents.
Most LCD screens have a very small and inconsequential defective pixel rate (usually 
less than 0.1%). This results in occasional pinpoints of white or other colors but will 
not affect the accuracy of measurements.

 

 
 
Do not disassemble or modify the battery.
Do not expose the battery to heat (fire) or water/moisture.
When disposing used/old batteries, wrap with insulation tape to shield the battery 
from electrical contact with metallic objects, which might ignite a fire or explosion.
If the unit is plugged into the power adapter and the battery seems to be 
overheating, or if there is smoke or peculiar odors emanating from the unit, unplug 
immediately to avoid the possibility of fire.
However, do not touch the cables if there is heat emanating from near the cables as 
melted or deformed cables could expose wiring and result in burns or electric shock.
Do not use cloth or anything to wrap or cover the equipment while charging – this 
could cause the unit to overheat, melting the casing or causing fire.
If the unit is accidently immersed in water, or if moisture has seeped inside, or metal 
objects have dropped into the casing, immediately remove the battery to avoid fire 
or electric shock.
Do not operate or store the battery in high-temperature environments - it will cause 
battery leakage and/or shorten the life of the battery .
Do not use paint thinner, benzene or other organic solvents to clean the equipment 
– this may damage the exterior finish or touch screen, and may even ignite fire.

Содержание MK550T

Страница 1: ...or modify the battery Do not expose the battery to heat fire or water moisture When disposing used old batteries wrap with insulation tape to shield the battery from electrical contact with metallic objects which might ignite a fire or explosion If the unit is plugged into the power adapter and the battery seems to be overheating or if there is smoke or peculiar odors emanating from the unit unplu...

Страница 2: ...er Battery Power Adaptor USB Cable User Manual Packing Contents SD Card Slot Power Key Reset Key Mini USB Power Jack Battery 3 5 Touch Screen Sensor Cover Product Description Light Sensor Measure Button Battery Cover Bracket ...

Страница 3: ... fully charged 2 1 Battery charging 1 Plug power charging cable into power jack to start charging 2 Power Off Status Users can check power key it will light in red while charging and off after being fully charged 3 Power On Status Users can check MK550T screen it will appear a lightning symbol to indicate charging and lightning symbol will disappear after being fully charged 3 charging Getting Sta...

Страница 4: ...to BASIC mode Next page taking a measurement Getting Started 4 Step1 Point sensor head at panel with suggest angle 0 Step2 Press the measure button Step3 Beeps once while execute dark calibration automatically The measurement progress is shown on the screen Step4 After twice beep sound measured data will be displayed on the screen save measured data Step1 Tap the save icon in the lower right corne...

Страница 5: ...data can be customized units of measure can be customized units of measure touch the graph to switch Option Function Setting Previous page Back to main manu Next page SD Card Ready Users can use storage function No SD Card System can t read the SD card or no SD card inside Remaining power displayed Adjust key Yes No End of the setting Date setting Time setting Language setting Power saving setting...

Страница 6: ...rement 1 Continuous measurement has no beep sound after press capture key 2 Users cannot save the measurement data while processing continuous measurement 3 Adjust the integration time is only allowed in the manual mode Step1 Select Continuous Step2 Point sensor head at panel with suggest angle 0 Press the measure button Step3 Processing the continuous measurement Step4 Press measure button again ...

Страница 7: ...lect OPTION Select USB mode USB connection uFLICKER PC software Select PC connection and perss Yes Connecting with uSPECTRUM Install uSPECTRUM PC software Install uSPECTRUM software on the PC Then you can connect it with the system for USB control of measurement Set USB PC connection mode Measure uSPECTRUM Install file Select OPTION Select USB mode USB connection uSPECTRUM PC software Select PC co...

Отзывы: