Page 2-7
Operation
- 2.6 - Maintenance
SL20
B
ATTERY
M
AINTENANCE
W A R N I N G
!
Hazard of explosive gas mixture. Keep sparks, flame, and smoking material away from
battery.
Always wear safety glasses when working with batteries.
Battery fluid is highly corrosive. Thoroughly rinse away any spilled fluid with clean water.
Always replace batteries with UpRight batteries or manufacturer approved replacements
weighing 28 kg. (62 lbs.) each.
• Check battery fluid level daily, especially if work platform is being used in a warm, dry climate.
• If electrolyte level is lower than 10 mm (3/8 in.) above plates, add distilled water ONLY. Do not
use tap water with high mineral content, as it will shorten battery life.
• The battery and cables should be inspected regularly for signs of cracks in the case, electro-
lyte leakage and corrosion of the terminals. Inspect cables for worn spots or breaks in the
insulation and for broken cable terminals. Keep terminals and tops of batteries clean.
• Refer to the Service Manual to extend battery life and for complete service instructions.
B
ATTERY
C
HARGING
Figure 2-7:
Power Module
Charge batteries at end of each work
shift or sooner if batteries have been
discharged.
W A R N I N G
!
Charge batteries in a well ventilated area.
Do not charge batteries when the work platform is in an area containing sparks or
flames.
Permanent damage to batteries will result if batteries are not immediately recharged
after discharging.
Never leave charger operating unattended for more than two days.
Never disconnect cables from batteries when charger is operating.
Keep charger dry.
Never operate machine while batteries are being charged.
1. Check battery fluid level. If electrolyte level is lower than 10 mm (3/8 in.) above plates add
distilled water only.
2. Connect extension cord to charger plug at end of left module. Connect extension cord 1.5
mm² (12 gauge)minimum conductor diameter; 15m (50 ft.) maximum length) to properly
grounded outlet of correct voltage and frequency.
NOTE:
Charger circuit must be
used with a GFI (Ground Fault
Circuit Interrupt) outlet.
3. Charger turns on automatically after a short delay.
NOTE:
Do not operate the
machine while the charger is
plugged in.
Battery Charger
Remove to check fluid level
Содержание SL20 Series
Страница 1: ......
Страница 10: ...Page viii Table of Contents List of Tables SL20 Work Platform NOTES ...
Страница 12: ...Page 1 2 Introduction 1 2 General Description SL20 NOTES ...
Страница 33: ...Page 3 11 Maintenance 3 11 Setting Hydraulic Pressures SL20 NOTES ...
Страница 61: ...Page 5 7 Schematics Hydraulic Schematic SL20 Figure 5 2 Plugs 4 ...
Страница 62: ...Page 5 8 Schematics SL20 NOTES ...
Страница 65: ...Page 6 3 Illustrated Parts Breakdown Final Assembly SL20 Drawing 2 of 3 ...
Страница 66: ...Page 6 4 Illustrated Parts Breakdown Final Assembly SL20 Drawing 3 of 3 ...
Страница 69: ...Page 6 7 Illustrated Parts Breakdown Chassis Assembly SL20 Drawing 1 of 2 ...
Страница 70: ...Page 6 8 Illustrated Parts Breakdown Chassis Assembly SL20 Drawing 2 of 2 ...
Страница 73: ...Page 6 11 Illustrated Parts Breakdown Linkage Assembly SL20 ...
Страница 75: ...Page 6 13 Illustrated Parts Breakdown Control Module Assembly SL20 ...
Страница 79: ...Page 6 17 Illustrated Parts Breakdown Control Valve Assembly SL20 ...
Страница 85: ...Page 6 23 Illustrated Parts Breakdown Platform Control Assembly SL20 Drawing 2 of 2 29 7 33 32 35 36 34 31 30 ...
Страница 91: ...Page 6 29 Illustrated Parts Breakdown Label Kit Installation SL20 ...
Страница 93: ...Page 6 31 Illustrated Parts Breakdown Label Kit German SL20 ...
Страница 95: ...Page 6 33 Illustrated Parts Breakdown Label Kit French SL20 ...
Страница 97: ...Page 6 35 Illustrated Parts Breakdown Label Kit Spanish SL20 ...
Страница 102: ...Page 6 40 Illustrated Parts Breakdown SL20 NOTES ...
Страница 103: ......