background image

03

NO.

Items

-20°C

Testing method

Internal resistance 

3

≤25mΩ

50% battery SOC state frequency of 1 KHZ ac 

resistance tester. 

Criterion

Discharge 
Temperature 
Characteristics

At 25±5°C discharge the battery with the current of 
0.33C to the cut-off voltage and record charge 
capacity. Store the battery at various temperatures 
for 2h and discharge the battery with 0.33C to the  
cut-off voltage.

0°C

25°C

55°C

≥70%

≥80%

≥100%

≥95%

Charge the battery to full capacity and store it for 28 
days, and then discharge it with 0.33C to the cut-off 
voltage.

Charge Retention 
ability

Residual

capacity ≥80%

Discharge with the current of 0.33C until it can’t 
discharge, and then rest it for 1h. Charge the battery 
following CC (1C)/CV (43.8V) mode to full capacity, 
and then rest it for 1h. Repeat above process until full 

charged capacity is no more than 80% of normal 

value. Accumulated times is defined as cycle life.

4

Cycle life (DOD%100)

≥2500 cycles

5

4. Product Performance

6

Recovery

capacity ≥90%

Rest for 1 hour after fully charged, then discharge with 
0.33C current until the battery reaches the discharge 
cutoff voltage. Repeat above process for three times, 
if the discharge time is not less than 180 minutes, you 
can stop and define the Discharging current*time 
value (Ah) as battery capacity.    

Rated Capacity 

1

80Ah

Minimum Capacity 

2

78.4Ah

UE-36Li80

www.upowerbatteries.com

66A Tzar Asen Srt.
Sofia, Republic of Bulgary
Tel. (+34) 918 021 649
Fax. (+34) 917 750 542
[email protected]

Содержание Ecoline UE-36Li80

Страница 1: ...f the battery pack NO Items Criteria 80Ah 78 4Ah 3 07KWh Rated Capacity Minimum Capacity Energy Floating charge voltage Internal resistance Limited charge voltage 38 4V 38 4V 41 4 0 2V 2 3 4 5 6 7 Nominal Voltage Outgoing Voltage 25mΩ 43 8 0 2V Standard charge current 80A 8 Maximum charge current 80A 9 Maximum discharge current 100A 10 Pulse discharge current 400 100A Continuous for 5 1s 11 Discha...

Страница 2: ... 3 1 1 Unless otherwise specified all performance tests is required conducted at temperature 25 C 2 C Humidity less than 45 75 RH 3 1 2 Unless otherwise specified the tested product is required unused within two month after outgoing 3 2 Standard Charge Mode Standard Charge means at 25 2 C charge to limit voltage with 1C constant current then charge with constant voltage until current less than 0 0...

Страница 3: ... can t discharge and then rest it for 1h Charge the battery following CC 1C CV 43 8V mode to full capacity and then rest it for 1h Repeat above process until full charged capacity is no more than 80 of normal value Accumulated times is defined as cycle life 4 Cycle life DOD 100 2500 cycles 5 4 Product Performance 6 Recovery capacity 90 Rest for 1 hour after fully charged then discharge with 0 33C ...

Страница 4: ... discharge release method Charging recovery UE 36Li80 5 Protective Circuit Specification The batteries are supplied with a LiFePO4 Battery Management System BMS that can monitor and optimized each single prismatic cell during charge discharge to protect the battery pack overcharge over discharge short circuit Overall the BMS helps to ensure safe and accurate running Items Over charge protection fo...

Страница 5: ...stayed in the warehouse 15ºC 35ºC where it s dry clean shade and well ventilated The battery should be stored in 50 SOC during transportation The battery need to be charged every 6 months if out of use Keep the battery against dropping turning over and serious stacking during loading www upowerbatteries com 66A Tzar Asen Srt Sofia Republic of Bulgary Tel 34 918 021 649 Fax 34 917 750 542 info upow...

Страница 6: ...se stop using and take it out from device If the battery leaks and get into the eyes or skin do not wipe instead rinse it with clean water and see doctor immediately Please far away from children or pets Do not put disuse battery into a fire or water Series connection of this battery pack is prohibited UE 36Li80 9 Battery Operation Instruction 9 1 Charge and discharge 9 1 1 Charging current Do not...

Страница 7: ...e not maintained within the specified ranges the life expectancy of the battery may be shortened or the device in which the battery is used may be damaged by electrolyte leakage If the discharge time is much shorter than the normal after full charged even battery is charged correctly and this may indicate it is time to change the battery UE 36Li80 www upowerbatteries com 66A Tzar Asen Srt Sofia Re...

Отзывы: