background image

02

UE-36Li100

NO.

Items

Description 

Length: 520±3mm

Width:   268±3mm

Height:  222±3mm

Dimension

Self-discharge rate

Operating Temperature 

Approx: 37.3±0.5Kg

Charging

0~45°C

Residual capacity

≤5%/month; ≤50%/years

14

15

16

Weight

Discharging

-20~60°C

Recommended operating temperature

15°C~35°C

Storage Temperature & Humidity Range

Less than 1 month

-20°C~45°C

45% RH

~75

% 

RH 

17

Less than 3 months

-10°C~35°C

45% RH

~75

% 

RH 

Recommended storage environment

:

15°C~35°C

45% RH

~75

% 

RH

13

Long time storage: 

If the battery need be stored for a long time, the voltage should be 39.6V (50% SOC), and stored in the 

condition as storage proposal. It need at least one charge & discharge cycle every six months

3. Test Conditions

3.1 Standard Test Conditions

3.1.1 Unless otherwise specified, all performance tests is required conducted at temperature 25°C±2°C,                   
         Humidity less than 45% ~ 75% RH.
3.1.2 Unless otherwise specified, the tested product is required unused within two month after outgoing.

3.2 Standard Charge Mode

"Standard Charge" means at 25±2°C charge to limit voltage with 1C constant current, then charge with 
constant voltage until current less than 0.02C. 

3.3 Quick Charge Mode

"Quick Charge" means at 25±2°C charge to limit voltage with 1C constant current, then charge with constant 
voltage until current less than 0.02C. 

3.4 Standard Discharge Mode

"Standard Discharge" means at 25±2°C discharge to the cut-off voltage with 1.25C current.

3.5 Quick Discharge Mode

"Quick Discharge" means discharge to the cut-off voltage with 1.25C current.

www.upowerbatteries.com

66A Tzar Asen Srt.
Sofia, Republic of Bulgary
Tel. (+34) 918 021 649
Fax. (+34) 917 750 542
[email protected]

Содержание Ecoline UE-36Li100

Страница 1: ...f the battery pack NO Items Criteria 100Ah 98Ah 3 84KWh Rated Capacity Minimum Capacity Energy Floating charge voltage Internal resistance Limited charge voltage 38 4V 38 4V 41 4 0 2V 2 3 4 5 6 7 Nomi...

Страница 2: ...3 1 1 Unless otherwise specified all performance tests is required conducted at temperature 25 C 2 C Humidity less than 45 75 RH 3 1 2 Unless otherwise specified the tested product is required unused...

Страница 3: ...an t discharge and then rest it for 1h Charge the battery following CC 1C CV 43 8V mode to full capacity and then rest it for 1h Repeat above process until full charged capacity is no more than 80 of...

Страница 4: ...ischarge release method Charging recovery UE 36Li100 5 Protective Circuit Specification The batteries are supplied with a LiFePO4 Battery Management System BMS that can monitor and optimized each sing...

Страница 5: ...tayed in the warehouse 15 C 35 C where it s dry clean shade and well ventilated The battery should be stored in 50 SOC during transportation The battery need to be charged every 6 months if out of use...

Страница 6: ...stop using and take it out from device If the battery leaks and get into the eyes or skin do not wipe instead rinse it with clean water and see doctor immediately Please far away from children or pet...

Страница 7: ...not maintained within the specified ranges the life expectancy of the battery may be shortened or the device in which the battery is used may be damaged by electrolyte leakage If the discharge time is...

Отзывы: