6. Dimensional Drawing     

Items

Over-charge protection for each cell

Specification

Content

3.80±0.03V

Over charge

Over-charge release for each cell

3.60±0.05V

Over-charge release method

Under the release voltage

Over-discharge protection for each cell

2.0±0.08V

Over discharge

Over-discharge release for each cell

2.3±0.1V

Over-discharge release method

Charging recovery

Discharge over current protection 

170~220A

Over current

Protection delay time

0.5 - 1.5s

Over current release method

Release after cutoff the load

Battery 
temperature

Charge over temperature 

Protection @65±5°C

Discharge over temperature

Release @55±15°C

Protection @65±5°C

Release @55±5°C

Short

No

Ban electrode short circuit