background image

UE-12Li75

6. Dimensional Drawing     

Items

Over-charge protection for each cell

Specification

Content

3.80±0.03V

Over charge

Over-charge release for each cell

3.60±0.05V

Over-charge release method

Under the release voltage

Over-discharge protection for each cell

2.0±0.08V

Over discharge

Over-discharge release for each cell

2.3±0.1V

Over-discharge release method

Charge to recovery

Discharge over current protection 

150~200A

Over current

Protection delay time

0.5 - 1.5s

Over current release method

Release after cutoff the load

Battery 
temperature

Charge over temperature 

Protection @65±5°C

Discharge over temperature

Release @48±10°C

Protection @65±5°C

Release @48±10°C

Short circuit

Do not short-circuit the electrodes

Designed For 400A~600A /300us

Charge over temperature protection MOS

Protection @100±5°C

Discharge over temperature protection MOS

Release @70±15°C

Protection @100±5°C

Release @70±15°C

01

01

01

04

www.upowerbatteries.com

66A Tzar Asen Srt.
Sofia, Republic of Bulgary
Tel. (+34) 918 021 649
Fax. (+34) 917 750 542
[email protected]