UE-12Li22BL
02
NO.
Items
Description
Length: 165±2mm
Width: 76±2mm
Height: 181±2mm
Dimension
Self-discharge rate
Operating Temperature
Approx: 3.0±0.3Kg
Charging
:
0~45°C
Residual capacity
:
≤3%/month; ≤15%/years
16
17
18
Weight
Discharging
:
-20~60°C
Recommended operating temperature
:
15°C~35°C
Reversible capacity
:
≤1.5%/month; ≤8%/years
Storage Temperature & Humidity Range
Less than 1 month
:
-20°C~35°C
,
45% RH
~75
%
RH
19
Less than 3 months
:
-10°C~35°C
,
45% RH
~75
%
RH
Recommended storage environment
:
15°C~35°C
,
45% RH
~75
%
RH
15
Long time storage:
If the battery need be stored for a long time, the voltage should be 13.2V (50% SOC), and stored in the
condition as storage proposal. It need at least one charge & discharge cycle every six months
Maximum discharge current
30A
12
Pulse discharge current
Withstand the 55A/3s
13
10V
14
Discharge cut-off voltage
3. Test Condition
3.1 Standard Test Conditions
3.1.1 Unless otherwise specified, all performance tests is required conducted at temperature 25°C±2°C,
Humidity less than 45% ~ 75% RH.
3.1.2 Unless otherwise specified, the tested product is required unused within two month after outgoing.
3.2 Standard Charge Mode
"Standard Charge" means at 25±2°C charge to limit voltage with 0.33C constant current, then charge with
constant voltage until current less than 0.02ItA.
3.3 Quick Charge Mode
"Quick Charge" means at 25±2°C charge to limit voltage with 0.5C constant current, then charge with
constant voltage until current less than 0.02ItA.