![UPOWER Ecoline UE-12Li100 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/upower-ecoline/ue-12li100/ue-12li100_manual_1061047004.webp)
UE-12Li100
6. Dimensional Drawing
Items
Over-charge protection for each cell
Specification
Content
3.75±0.025V
Over charge
Over-charge release for each cell
3.60±0.04V
Over-charge release method
Under the release voltage
Over-discharge protection for each cell
2.0±0.04V
Over discharge
Over-discharge release for each cell
2.5±0.04V
Over-discharge release method
Charge to recovery
Discharge over current protection
420~480A
Over current
Protection delay time
20 - 40ms
Over current release method
Delay about 10S after recovery
Battery
temperature
Charge over temperature
Protection @65±5°C
Discharge over temperature
Release @50±5°C
Protection @65±5°C
Release @50±5°C
Short circuit
Do not short-circuit the electrodes
Designed For 480A~700A /500us
Charge over temperature protection MOS
Protection @103±10°C
Discharge over temperature protection MOS
Release @75±10°C
Protection @103±10°C
Release @75±10°C